Operating Instructions - SATA jet 100 B Mode D'emploi

Masquer les pouces Voir aussi pour jet 100 B:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
Operating instructions SATAjet 100 B F (RP/HVLP), B P
Preface
Prior to putting the unit/paint spray gun into operation, read the operating instructions
completely and thoroughly. The stipulations contained therein are to be respected in any case.
After that, the operating instructions are to be stored in a safe place, accessible for every user of
the equipment. The unit/paint spray gun may only be put into operation by persons familiar with
its use (professionals). Inappropriate use of the unit/paint spray gun, modification of any kind or
combination with inappropriate other parts may cause material damage, serious hazard to the
user's, other person's or animal's health or even death. SATA shall not take any responsibility for
such damages (e.g. failure to respect the stipulations laid out in the operating instructions). The
applicable safety, workplace and worker health protection regulations of the respective country or
area/district in which the system/the paint spray gun is used are to be respected in any case (e.g.
the German Rules for the Prevention of Accidents BGR 500 (BGV D25) and BGV D24 issued by
the Central Office of the Professional Trade Associations, etc.). SATA, SATAjet, the SATA Logo
and/or other SATA products referenced herein are either registered trademarks or trademarks of
SATA GmbH & Co. KG in the U.S. and/or other countries. The names of companies and products
mentioned herein may be the trademarks of their respective owners.
Only with DIGITAL version: Opening will lead to expiry of the explosion hazard safety certificate
and the warranty.
To be noted
Never point paint spray guns at yourself, at other persons or animals. Solvents and thinners can
cause burns. Only the respective quantities of solvents and paints required for work progress may
be present in the direct surroundings of the unit (after work, solvents and paints are to be returned
to their assigned storage rooms). Prior to any repair work the unit must be disconnected from the
air supply. Prior to putting the unit into operation, especially after each cleaning and each repair
work, check all screws and nuts for tight fit, as well as the sealing performance of the spray guns
and hoses. Defective components must be replaced or repaired accordingly. To obtain best pos-
sible coating results, and for maximum safety, only use original spare parts. No sources of ignition
(e.g. open flames, burning cigarettes, lamps without ex-protection etc.) may be present during
painting, as easily flammable mixture are generated during the painting process. Occupational
safety regulations must be applied when painting (respiratory protection, etc.). Appropriate ear
protection muffs are required, as a sound level of 90 dB(A) is exceeded when coating with higher
pressure levels. No vibration is transmitted to the upper parts of the operator's body during use of
the paint spray gun. Recoil forces are negligible. The use of this product in explosion hazard
areas Zone 0 is prohibited.
1. Features and technical Data (General)
• 0,6 l QCC quick change gravity flow cup
(plastic) with integrated non-drip device
• Tool kit
• Alternatively: 1.0 l aluminum cup (QCC)
without swivel joint
1.1 Technical Data (RP version)
• Spray gun with nozzle 1,6 RP
• Air consumption: 10.2 cfm at 29 psi
• Recommanded gun inlet pressure
1,5 - 2,0 bar /21.8 - 29 psi
(Spot Repair 0,5 - 1,5 bar/7.3 - 21.8 psi)
• Maximum temperature of
the coating material 122° F
• Technical maximum gun inlet pressure
10 bar/145 psi
1.2 Technical Data (HVLP version)
• Spray gun with nozzle 1,7 HVLP
• Air consumption: 12.4 cfm at 2 bar/29 psi
• Recommanded gun inlet pressure
2 bar/29 psi - (HVLP)