Maximum Programmable Values Vgp25N; Factory-Set Values Vgp25N; Visual Warnings Vgp25N; Information Displayed At Start-Up Vgp25N - Orved VGP25N Mode D'emploi Et D'entretien

Thermosoudeuse de barquettes en atmosphère modifiée
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

OPERATION VGP25N

7.1.1 MAXIMUM PROGRAMMABLE VALUES VGP25N

FUNCTION
VACUUM
ADDITIONAL VACUUM
SEALING
GAS INJECTION
7.1.2 FACTORY-SET VALUES
The factory settings that appear upon the first start-up are described below. These values can be changed or integrated
via programming, in which case they are overwritten.
The factory settings can be restored at any time by resetting.
Vacuum-gas program: VAC 100% / VAC+ 5 sec. /GAS 100% / sealing 4,0 seconds.
Only sealing program: VAC / VAC+ /GAS / GAS+: OFF, sealing 4,0 seconds.

7.2 VISUAL WARNINGS VGP25N

The 12 LEDs and the two displays allow a number of useful messages relative to identification of the program status the
machine is operating.
Upon the two displays, in addition to the functions inherent the performed working cycle, further more important in-
formation such as serial number, the number of cycles performed by the machine before changing the oil, the software
version installed displayed and/or can be recalled.

7.2.1 INFORMATION DISPLAYED AT START-UP VGP25N

Upon start-up, the information below is displayed in sequence:
• Software version installed.
• Pump status on/off.
• Set program.
• Number of cycles performed daily. The the cycle counter is reset upon each start-up.
WARNING!
• Along with the above mentioned signals, an alarm message to change the pump oil is displayed upon
start-up if the maximum number of cycles admissible has been reached (see next § 7.2.2).
• If a functioning anomaly occurs with an overheating of the pump, the relative alarm is displayed immediately
and the machine does not accept controls until the anomaly has been cleared.

7.2.2 DISPLAY OF THE NUMBER OF CYCLES PERFORMED BEFORE THE OIL MUST BE REPLACED VGP25N

To recall the exact number of cycles performed by the machine, turn on the machine
and press the "PUMP" and "STOP" buttons together.
The lower display will show the number of cycles performed since the last reset.

7.2.3 DISPLAY OF THE SERIAL NUMBER VGP25N

To recall the serial number of the machine, press the " PUMP" and " STOP" buttons together.
30
VGP25N
Rev. 08 - 04/2017 - Cod. 1500160 - Instruction manual VGP25N / VGP60N
PROGRAMMABLE VALUES
0 - 100%
0 - 60 sec
1 - 9.9 sec
0 - 110%

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vgp60n

Table des Matières