Homogenisation Of Samples; Setting The Shaking Frequency; Setting The Operation Time - Sartorius Stedim Biotech Mikro-Dismembrator S Mode D'emploi

Homogénéisateur broyeur vibrant
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.3

Homogenisation of samples

3.3.1 Switching-on the Mikro-Dismembrator S
e Mikro-Dismembrator S
Fig. 5: Operating panel of the Mikro-Dismembrator S
Fig. 5: Operating panel of the Mikro-Dismembrator S
with key pad
with key pad
1.
1.
Switch-on the Mikro-Dismembrator S with the mains
Switch-on the Mikro-Dismembrator S with the mains
switch on the rear of the unit. The homogenizer starts
switch on the rear of the unit. The homogenizer starts
with the operation mode, selected when the unit was
with the operation mode, selected when the unit was
switched-off the last time, i.e. "Timer Mode" or
switched-off the last time, i.e. "Timer Mode" or
"Frequency Mode". The modes can be distinguished by
"Frequency Mode". The modes can be distinguished by
the data shown on the display. The "Timer-Mode"
the data shown on the display. The "Timer-Mode"
displays the time [TIME 00:00 Min:Sec], the
displays the time [TIME 00:00 Min:Sec], the
"Frequency-Mode" displays [RPM X.XXX]). You can
"Frequency-Mode" displays [RPM X.XXX]). You can
switch-over to the other mode with either the key [
switch-over to the other mode with either the key [
or [
or [
].
].
2.
2.
Enter the operation time and shaking frequency via the
Enter the operation time and shaking frequency via the
numeric keys. See fig. 5 and the following paragraphs.
numeric keys. See fig. 5 and the following paragraphs.
3.
3.
Close the cover and the clamps which fix the cover
Close the cover and the clamps which fix the cover
(see fig. 1, pos. 6).
(see fig. 1, pos. 6).
The Mikro-Dismembrator S can not be started, when
the cover is open. A cut-off switch opens when the
cover is open and switches-off the unit, when running,
or prevents it from being started, respectively.
The safety switch must not be disabled!
3.3.2
12

Setting the Shaking Frequency

1.
Switch into "Frequency-Mode" with key [
the unit is in "Timer-Mode".
2.
Enter the shaking frequency required via the numerical
keys. The value range is:
Mikro-Dismembrator S
100...2.600
continuous mode
3.
Confirm the entry with the [ENTER] key. Wrong inputs
can be easily corrected. Press deletion key [ C ] to
change the actual entry. The cursor starts with the last
(right hand) digit of the display, ready for a new entry.
Confirm new entry with the [ENTER] key.

3.3.3 Setting the Operation Time

]
]
1.
Switch-over to "Timer-Mode" with either key [
[
] if the Mikro-Dismembrator S is in "Frequency-
Mode".
2.
Enter the operation time in [Min:Sec] via the numeric
key pad. The timer value range is 00:01 ... 98:59
[Min:Sec]. Press the [ENTER] key to confirm the value
time. For a quick entry of the time, you may confirm
after input of [Min].
3.
Wrong inputs can be easily corrected. Press deletion key
[ C ] to change the actual entry. The cursor starts with
the first (left hand) digit of the display, ready for a new
entry of [Min]. Confirm new entry with the [ENTER] key.
The Mikro-Dismembrator S remains inactive at an input
of 00:00 [Min:Sec]. Illogical inputs will be ignored, such
as 00:70 [Min:Sec], for instance. The input of 99:59
[Min:Sec] switches-over to "Timer-Mode" for
continuous operation.
3.3.4
1
/min
100...3.000
fixed operation times in
timer mode
] or [
] if
1
/min
] or

Publicité