Target Count

Network High Speed Dome "Target Count" setting interface as shown in the figure below.
Enable: enable or disable the target counting function.
Arming Schedule: arming schedule can be set from Monday to Sunday.
Area Setting: in the "Area Setting" preview interface, click "drawing", click the left mouse button to set the detection line, then right-
click to complete; the target will be counted when going through the line.
Clear: click Clear to delete all the test lines.
Swap AB: click "swap AB" to exchange positions between A and B.
Test Line: to add new test lines (max. 4 test lines supported), or set the parameter setting for the corresponding test line option.
Statistics: set the test lines for targets passing through; there are two statistical methods, A→B and B→A..
Flow Count: enable or disable the Flow Count function.
Interval: set the counting time interval. When the time interval elapses, the flow counter will reset and enter into the next counting
period automatically.
Threshold: set the upper limit value for counting. When it is more than the setting value, it will trigger the alarm function
automatically.
Total Count: enable or disable the Total Count function.
Time: set the effective time period for the day's total count.
Alarm Threshold: set the upper limit value for the day's total flow. When it is more than the set value, it will trigger the alarm
function automatically.
Target Percent: set the min. area percentage for the effective counting targets. Once the area of targets passing through the test
line is smaller than the set value, it will be invalid without being counted.
Email: click Email. Once the alarm triggers, it will send an Email to the appointed mailbox.
Snap: click Snap. Once the alarm triggers, it will cause the linked camera to take a snapshot and store it on the micro-SD card.
Record: click Record. Once the alarm triggers, it will cause the linked camera to record a video and store it on the micro-SD card.
Alarm Output: there is an active warning device connected to the alarm output port. Once the alarm triggers it will cause the linked
embedded relay switch to execute an alarm output.
PTZ: enable or disable PTZ function.
Preset: when target counting triggers the alarm, it will link the presets.
Snap Interval: set the snapshot interval time.
Snap Number: set the snapshot image count for every time.
After all parameter settings have been completed, click "Save" and they will come into effect immediately.