DESCRIPTION OF THE PRODUCT
1
ELEMENTS OF THE COMPLETE INSTALLATION
TA
INSTALLATION COMPONENTS:
1
Operator
2
Flashing light with antenna
3
Leaves
4
Exterior photocells
5
Key switch
6
Wall pushbutton
7
Control board
8
Connections box
9
Electrical installation
10 Interior photocells
11 Electrolock
12 Stop on closing
ELECTRICAL WIRING:
Element
A: Main power supply
B/F: Flashing light with antenna
C: Photocells (Tx/Rx)
D: Key switch
E: Operator
G: Electrolock
Fig. 1
Elements of the complete installation
The safe and correct operation of the
installation is the responsibility of the installer.
TC
TC
G
The electrolock is obligatory in
unlocked models, and also in
locked models when the leaves
are over 1.80 m long.
Nº wires x section
2
3x1.5mm
2
2x0.5mm
/ coaxial cable 50k (RG-58/U)
2
2x0.5mm
/ 4x0.5mm
2
2x0.5mm
2
4x0.75mm
2
2x0.75mm
TA
TA
TA
VERY IMPORTANT: The TC
closing stopper and the TA
opening stoppers must be
installed in all cases.
2
For greater safety, Erreka recommends installing the
photocells (4) and (10).
English
E240A
Maximum length
30 m
10 m
30 m
25 m
20 m
20 m
VULCAN D Hydraulic operator
31