Erreka VULCAN D Manuel De L'installateur page 43

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Connect the operator to the control board
1
Motor connection (common)
2
Motor connection (Turn 1)
3
Motor connection (Turn 2)
4
Earth
Since this is a stationary unit for
permanent connection, an external cut-
off must be fitted.
Position the cover and tighten the gland
125V: 30µF
230V: 10µF
P240U
Before making any electrical connections,
check the control board instructions manual.
We recommend using the VIVO-M101(M) or VIVO-
M201(M) control boards.
The connection of an operator in the VIVO-
M201(M) control board is shown as an example. If a
single operator is used, use cable connectors G1, G2
and G3.
1 Connect the operator to the control board using
cable connectors G1, G2 and G3.
2 Connect the capacitor (C) to cable connectors G1
and G2.
3 Connect the control board to the electricity supply.
4 Activate the power supply switch.
Before carrying out any gate movement,
ensure there is no person or object in the radius
of action of the gate and the drive mechanisms.
5 Use the PUL1-PUL2 control board mini-pushbuttons
(CLOSE-OPEN) to check the motor connections are
correct (turning direction).
If
the
turning
direction
interchange cables 2 and 3.
Ensure the earth cable is properly connected.
1 Position the cover (1) in its housing (2) and secure
with the screws (3).
2 Tighten the gland (4) to ensure the electrical cable
input (5) is seal tight.
INSTALLATION
is
not
correct,
VULCAN D Hydraulic operator
43

Publicité

Table des Matières
loading

Table des Matières