DESCRIPTION OF THE PRODUCT
1
ELEMENTS OF THE COMPLETE INSTALLATION
INSTALLATION COMPONENTS:
1
Operator
2
Flashing light
3
Exterior photocells
4
Key switch
5
Wall pushbutton
6
Switchboard
7
Connections box
8
Interior photocells
9
Electrolock
10 Stop on closing
11 Antenna
We recommend using the VIVO-M201(M) or VIVO-M101(M) switchboard for the 125/230VAC models
and the VIVO-D201(M) switchboard for the 24VDC models.
ELECTRICAL CABLING:
Element
A: Main power supply
B: Flashing light
C: Photocells (Tx / Rx)
D: Pushbutton or key switch
E: Operator (125/230 VAC)
E: Operator (24VDC)
F: Antenna
Fig. 1
Elements of the complete installation
The safe and correct operation of the
installation is the responsibility of the installer.
Nº wires x section
2
3x1.5mm
2
2x0.5mm
2
2
2x0.5mm
/ 4x0.5mm
2
2x0.5mm
2
4x1mm
2
2x1mm
Coaxial cable 50k (RG-58/U)
Maximum length
30m
20m
30m
25m
20m
8m (maximum 25m with cable 2x2.5mm
5m
For greater safety, Erreka recommends installing the
photocells (3) and (8).
2
)
ARES electro-mechanical operator
English
27