5
PEDESTRIAN OPENING RUN PROGRAMMING
Programming the pedestrian opening run can be done using the ST2 mini-pushbutton, the A.P. key or the
transmitter.
The programming of the total opening run must be complete.
If the gate collides with an obstacle during programming, repeat the programming process.
Before making the programming, ensure there is no person, animal or object in the radius of action of
the gate and the mechanism.
Start programming mode
Programme opening
Programme closing
Finish the programming mode
1 Place DIP1 and DIP3 in "OFF".
DL3 will remain off.
The pedestrian opening position will be
memorised.
PROGRAMMING AND STARTUP
1 Close the gate by pressing PUL1.
2 Place DIP1 and DIP2 in "ON" (pedestrian opening
programming); DIP3, DIP4, DIP6 and DIP7 in "OFF".
DL3 lights up, statically.
3 Installations with electrolock: place DIP5 in "ON"
(back pulse).
4 In operators with mechanical absorbers (such as
hydraulic motors), place DIP8 in "OFF" (electric soft
stop disabled).
1 Start opening: press ST2; the gate begins to open.
2 Start soft stop in opening (only if DIP8=ON):
press ST2 at the point chosen for the start of
deceleration (DA).
3 Finish opening: Press ST2 in the gate open
position.
1 Start closing: press ST2; the gate begins to close.
2 Start soft stop in close (only if DIP8=ON): press
ST2 at the point chosen for the start of deceleration
(DC).
3 Finish closing: Press ST2 in the gate closed position.
The positions in which the leaf begins to slow
down, both in opening and in closing, are also
memorised (only if DIP8=ON).
Control board VIVO-M101(M)
51