INSTALLATION
Peripheral connections
SMF
Signal light card (EPS1-001)
ANT
Antenna connector
R.E.
Plug-in receiver
A.T. (ST1) Key device
S.EXT (FT1) Exterior safety device (photocell or
mechanical strip)
A.P. (ST2) Pedestrian operation device
S.INT (FT2) Interior safety device (photocell or
mechanical strip)
FCA
Opening limit switch
FCC
Closing limit switch
46
Installation Manual
P1 P2 P3
P4 P5 P6
P15 P14 P16
ST1
FT1
ST2
FT2
FCA1
ST1
FT1
ST2
FT2
Check the accessory instructions to carry out the connections.
P7 P8
P11 P12
P22 P23
G7 G8
G9 G10
Courtesy
24Vac
Lamp.
FCC1
STOP
LOCK
Light
VIVO-M101:
230Vac
VIVO-M101M:
125Vac
STOP Emergency stop pushbutton (normally closed)
EC
Electrolock (17Vdc)
AUX Output (24Vac, 0.35A)
LG
Garage light (courtesy light)
VIVO-M101: 230Vac, max. 2,300W resistive
VIVO-M101M: 125Vac, max. 1,250W resistive
DEST Flashing light (max. 40W resistive)
VIVO-M101: 230Vac
VIVO-M101M: 125Vac
SW1
Main switch
G1
G2
G3
N
L
POWER
MOTOR1 (G2-G1-COM)
(resistive)
VIVO-M101: 230Vac
VIVO-M101M: 125Vac
VIVO-M101:
max 2.300W
VIVO-M101M:
max 1.250W
(resistive)
P170Z