3
FUNCTIONING MODES
Step-by-step mode (DIP4=OFF and DIP10=OFF)
(in pedestrian and total operation)
Opening: this begins by activating the key device
(transmitter, magnetic key, key switch, etc).
• Step-by-step opening (DIP3=ON): if the key
device is activated during opening, the gate comes
to a stop. The gate closes if activated again.
• Community
opening
opening, the control board does not obey the key
commands.
Automatic mode (DIP4=ON)
(in pedestrian and total operation)
Opening: this begins by activating the key device
(transmitter, magnetic key, key switch, etc).
• Step-by-step opening (DIP3=ON): if the key
device is activated during opening, the gate comes
to a stop. The gate closes if activated again.
• Community
opening
opening, the control board does not obey the key
commands.
Dead man mode (DIP4=OFF and DIP10=ON)
In this case the gate cannot be operated using the transmitter.
Opening: it is necessary to keep the A.T. total opening
button pressed down (ST1). The gate will stop if the
pushbutton is released.
(DIP3=OFF):
during
(DIP3=OFF):
during
DESCRIPTION OF THE PRODUCT
Standby: the gate remains open until a key command
is received.
Closing: closing starts by running the key device.
If the key device is activated during closing, the gate
reverses operation direction and opens completely.
S t a n d b y : t h e g a t e r e m a i n s o p e n d u r i n g t h e
programmed time.
• DIP6=OFF: standby time starts again if the safety or
key device is activated during standby.
• DIP6=ON (automatic mode optional): if the key
device is operated during standby, the gate begins
to close after 3 seconds. Standby time starts again if
the safety device is activated.
• DIP11=ON (interlock mode):
– DIP10=OFF: if, during standby, the exterior
photocell detects that a person or object has
passed, the gate begins to close.
– DIP10=ON: if the exterior and interior photocells
detect that a person or object has passed during
standby, the gate begins to close.
Closing: closing starts at the end of standby time (or
when running the key device if DIP6=ON, or when a
person or object passes through if DIP11=ON).
If the key device is activated during closing, the gate
reverses operation direction and opens completely.
Standby: the gate remains open indefinitely until the
pushbutton is pushed.
Closing: it is necessary to keep the A.P. pedestrian
opening button pressed down (ST2). The closing
operation is carried out at a single speed (there is no
slowdown towards the end).
Control board VIVO-M101(M)