Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

MAINTENANCE AND DIAGNOSIS OF FAILURES
Problem
The control board does not
work and no LED indicator comes
on
The operator does not work,
DL14 lit up,
DL6 and/or DL9 off
The operator does not work,
DL14 lit up,
DL6 and DL9 lit up,
DL10
and
DL11
operating the key devices
The operator does not work,
DL14 lit up,
DL6 and DL9 lit up,
the relay is activated (DL4 or DL5
and DL17 light up) when pressing
PUL1, PUL2
The leaf does not reach the
stopper
The electrolock is not released
3

SPARE PARTS

If the control board needs repairing, go to an
authorised assistance centre or manufacturer;
never try to repair it yourself.
4

SCRAP

The control board, up until the end of its useful
life, must be dismounted at its location by an
installer who is as well qualified as the person
who completed the assembly, observing the
same precautions and safety measures. In this
manner possible accidents and damage to
adjacent facilities will be avoided.
54
Installation Manual
Cause
Main switch SW1 in "OFF"
Absence of control board power
supply
Electronic fuse F2 blown
Transformer or board failed
D L 6 a n d / o r D L 9 o f f i n d i c a t e
obstacle or safety device error
F3 blown (whenever the safety
devices are fed by way of the AUX
24Vac control board connector)
The key device signal does not
reach the control board
off
when
F1 motor fuse blown
Operator connections
Operator defective
Open/close programming incorrect
Limit switches wrongly adjusted
The back pulse has not been
programmed
Electrolock or connections with
failure
Solution
Place SW1 in "ON"
Reestablish the power supply
Replace F2 using another fuse of
the same value and investigate the
cause of failure of F2
Call the technical service
Remove the obstacle or check the
interior/exterior safety devices
Replace F3 using another fuse of
the same value and investigate the
cause of failure of F3. Check that
the connected devices do not
represent an overload
C h e c k t h e d e v i c e s a n d t h e
connections
Replace F1 using another fuse of
the same value and investigate the
cause of failure of F1
Check connections
Replace operator
C a r r y o u t t h e p r o g r a m m i n g
correctly
Adjust the limit switches
Place DIP5 in ON
C h e c k t h e c o n n e c t i o n s a n d
electrolock
Use only original spare parts.
}
The control board must be deposited in the
appropriate containers for subsequent recycling,
separating and classifying the different materials in
line with their nature. NEVER deposit it in domestic
rubbish or in landfills which are not suitably
controlled, as this will cause environmental
contamination.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vivo-m101m

Table des Matières