Symbols On The Unit And Product Label; Functions - human care Roomer S Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 39

Symbols on the unit and product label

CE marking
f
Date of manufacture
g
Manufacturer
h
Max. load
j
Instructions: Read the instructions
and make sure you understand them
before using this product
Article number/reference number
l
Serial number
n

Functions

Emergency stop
In an emergency, the emergency stop can be
activated by pressing the RED button. To reset
the emergency stop, turn the RED button
clockwise.
Emergency lowering
In event of an emergency the emergency low-
ering function can be used. Press emergency
lowering button and down button at least 3
seconds simultaneously to activate the emer-
gency lowering. Older lifts (before july 2016)
may not have double key command and delay.
An audio signal indicates that the lift is lowering.
Always ensure that emergency lowering can be
performed as safely as possible for the patient.
The emergency lowering button only works
when the lift is switched on and emergency stop
has been deactivated. When the emergency
lowering is active, the end position switches are
inactive. If the button is pushed until the lift is
in its lowest position, the lift will start to go up
again. Always stop at the lowest position.
26
Medical Device
MD
Warning
o
The lift contains lead batteries and
q
electronics and it must be recycled
appropriately
Third party certification marking
(not applicable for all regions and
versions)
Type-B product
p
Switch the product off/Switch the
product on
The emergency lowering button
o
must only be used in emergency
situations.
Safety catch
The lift is equipped with a safety catch. This
prevents involuntary falls. If the lift belt is
pulled out too quickly, the safety catch will
engage, thus preventing the fall. Slacken the lift
belt to unlock the catch. With the safety catch
engaged, the lever (10) can never be turned, as
this blocks the lowering function of the lift!
Mechanical emergency lowering
During power loss and the hoist is loaded, user in
the hoist, the mechanical emergency lowering is
activated and the hoist is lowering in a safe and
reliable manner.
Overheating
The lift has overheating protection which stops
the motor if it gets too hot. Overheating can
occur if the motor is overloaded or operated
continuously for quite a long time. The lift's
work cycle (work:pause) is 15:85. Maximum
continuous operation is two minutes. If this
www.humancaregroup.com
ENG
ENG

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

5530055300h

Table des Matières