Anybus indicators
DeviceNet
#
Item
1
Network status LED
2
Module status LED
3
DeviceNet connector
4
M12 Female connector
5
M12 Male connector
Network Status
State
Indication
Off
Not online / No power
Green
On-line, one or more connections are
established
Flashing Green (1 Hz)
On-line, no connections established
Red
Critical link failure
Flashing Red (1 Hz)
One or more connections timed-out
Alternating
Self test
Red/Green
Module Status
State
Indication
Off
No power
Green
Operating in normal condition
Flashing Green (1 Hz)
Missing or incomplete configuration,
device needs commissioning
Red
Unrecoverable Fault(s)
Flashing Red (1 Hz)
Recoverable Fault(s)
Alternating
Self test
Red/Green
DeviceNet Connector
This connector provides DeviceNet connectivity
Pin
Signal
1
V-
2
CAN_L
3
SHIELD
4
CAN_H
5
V+
Description
Negative bus supply voltage
CAN low bus line
Cable shield
CAN high bus line
Positive bus supply voltage
EtherNet IP
#
Item
1
Network status LED
2
Module status LED
3
Link/Activity
4
Ethernet Interface
Network Status LED
LED State
Description
Off
No power or no IP address
Green
On-line, one or more connections
established (CIP Class 1 or 3)
Green, flashing
On-line, no connections established
Red
Duplicate IP address, FATAL error
Red, flashing
One or more connections timed out (CIP
Class 1 or 3)
Module Status LED
Note: A test sequence is performed on this LED during
startup
LED State
Description
Off
No power
Green
Controlled by a Scanner in Run state
Green, flashing
Not configured, or Scanner in Idle state
Red
Major fault (EXCEPTION-state, FATAL
error etc.)
Red, flashing
Recoverable Fault(s)
LINK/Activity LED
LED State
Description
Off
No link, no activity
Green
Link established
Green, flickering
Activity
16