- Every time the boiler is powered, an automatic bleed cycle begins
(lasting about 2 minutes). The display will simultaneously show: 43
and
. Press the
key to interrupt the automatic venting cycle. If
the check is correctly terminated, the boiler will be ready to operate
at the end of the automatic venting cycle. The boiler switches back
on in the status it occupied before switch-off. If the boiler is in the
heating mode when it is turned off, it turns back on in the same
mode; if it is OFF, the display will show ENERGY FOR LIFE.
- Press the
key to activate operation.
- Press the key
and turn the encoder A to select the required
heating water temperature.
The large digits will light up on the display, indicating the selected
temperature value.
Adjusting the heating temperature with an external probe
connected
If an external probe is present, the delivery temperature is
automatically selected by the system, which adjusts the ambient
temperature according to variations in the outside temperature.
The display shows the external probe icon, and only a central
segment is lit up in the heating comet.
If you want to modify the temperature value, increasing or reducing
it in relation to the value automatically calculated by the electronic
card, proceed as follows:
- press the heating temperature adjustment key
will show the number corresponding to the set comfort level
(factory setting).
- turn the encoder A to raise or lower the chosen comfort level (the
number +1, +2 etc.. or -1, -2 etc. appears on the two digits B,
corresponding to the chosen comfort level). The segment lit up in
the heating comet will rise or fall. The correction range is between
- 5 and + 5 comfort levels.
These corrections are very important in the mid-seasons, when the
value calculated by the curve may be too low and the room heating
time therefore too long. When 3 seconds have passed since the last
modification, the value is automatically stored and the display again
shows the value measured instantaneously by the probe.
Adjustment of the domestic hot water temperature
- Press the key
A
Operation
- Press the
The following conditions may occur:
- if there is no heat request the boiler will be in "standby"
- if there is a heat request, the boiler will start up and one of the
The Family Aqua Condens 3.5 BIS boiler will continue to function
until the adjusted temperatures are reached, after which it will be in
"standby".
If there are any firing or operation faults, the boiler will make a "safety
stop"; the display will show a flashing code and the RESET and
icons will appear (simultaneously or otherwise).
For the description of the fault and to reset the starting conditions see
the section "Display and fault codes".
. The two digits
and turn the encoder A to select the required DHW
temperature. The large digits will light up on the display, indicating
the selected temperature value. After a few seconds, the display
will again show the outlet temperature actually measured by the
boiler probe. The display will show the storage tank temperature
only when the domestic water icon is flashing. The display indicates
the storage tank temperature if there is a heat request from the
domestic water system. At the end of a storage tank heating cycle
therefore, the tap icon on the domestic water comet switches off
and the display shows the outlet temperature (that may fall well
below the temperature of the storage tank domestic hot water).
key to select the type of operation. Depending
on the type of operation chosen, the display will visualise just
the domestic water comet (heating function deactivated) or both
comets (heating function activated).
flames will light up according to the type of request. The display
indicates the temperature in the boiler, or the temperature of the
domestic hot water if the firing is due to a domestic water request.