Family Aqua Condens 3.5 BIS
N°
DESCRIEREA PARAMETRILOR
PAR
1
PARAMETRU CARE NU SE UTILIZEAZĂ LA ACEST MODEL, NU MODIFICAŢI PROGRAMAREA
2
PARAMETRU IRELEVANT
3
GRADUL DE IZOLAŢIE A CLĂDIRII
10
MOD APĂ MENAJERĂ
11
PARAMETRU CARE NU SE UTILIZEAZĂ LA ACEST MODEL, NU MODIFICAŢI PROGRAMAREA
VALOAREA MAXIMĂ PUNCT DE REFERINŢĂ
12
APĂ MENAJERĂ BOILER
13
TEMPERATURĂ TUR BOILER
14
DELTA BOILER
20
MOD ÎNCĂLZIRE
21
VALOAREA MAXIMĂ PUNCT DE REFERINŢĂ ÎNCĂLZIRE
22
VALOAREA MINIMĂ PUNCT DE REFERINŢĂ ÎNCĂLZIRE
VITEZĂ MAXIMĂ VENTILATOR ÎNCĂLZIRE
23
(reglare Gama nominală)
24
VITEZĂ MINIMĂ VENTILATOR ÎNCĂLZIRE
25
DIFERENŢIALĂ ÎNCĂLZIRE POZITIVĂ
26
DIFERENŢIALĂ ÎNCĂLZIRE NEGATIVĂ
28
TEMPORIZARE PUTERE MAX ÎNCĂLZ.REDUSĂ
29
TEMPORIZARE OPRIRE FORŢATĂ ÎNCĂLZ.
FUNCŢIA DE ADUCERE LA ZERO A
30
TEMPORIZATORULUI DE ÎNCĂLZIRE
VALOAREA MAXIMĂ PUNCT DE REFERINŢĂ
31
ÎNCĂLZIRE 2CH (circuitul II)
VALOAREA MINIMĂ PUNCT DE REFERINŢĂ
32
ÎNCĂLZIRE 2CH (circuitul II)
35
DIFERENŢIALĂ ÎNCĂLZIRE POZITIVĂ 2CH (circuitul II)
36
DIFERENŢIALĂ ÎNCĂLZIRE NEGATIVĂ 2CH (circuitul II)
40
PARAMETRU CARE NU SE UTILIZEAZĂ LA ACEST MODEL, NU MODIFICAŢI PROGRAMAREA
41
PARAMETRU CARE NU SE UTILIZEAZĂ LA ACEST MODEL, NU MODIFICAŢI PROGRAMAREA
42
FUNCŢIA C.T.R.
43
MEMORY ÎNCĂLZIRE
44
FUNCŢIA DE TERMOREGLARE
45
ÎNCLINAREA CURBEI DE TERMOREGLARE (OTC)
46
FUNCŢIA DE TERMOREGLARE 2CH
47
ÎNCLINAREA CURBEI DE TERMOREGLARE (OTC) 2CH
48
PARAMETRU CARE NU SE UTILIZEAZĂ LA ACEST MODEL, NU MODIFICAŢI PROGRAMAREA
50
PARAMETRU CARE NU SE UTILIZEAZĂ LA ACEST MODEL, NU MODIFICAŢI PROGRAMAREA
51
TIPUL CERERII DE CĂLDURĂ CH1 (circuitul I)
52
TIPUL CERERII DE CĂLDURĂ CH2 (circuitul II)
61
PARAMETRU CARE NU SE UTILIZEAZĂ LA ACEST MODEL, NU MODIFICAŢI PROGRAMAREA
62
TEMPER. TUR FUNCŢ. ÎNCĂLZIRE (ON)
63
TEMPER. TUR FUNCŢ. ANTI-ÎNGHEŢ BOILER (ON)
65
REACTIVITATE SONDĂ EXTERNĂ
120
UNITATE de
MIN
MĂSURĂ
10 (10kW*)
16 (16kW)
20 (20kW*)
26 (25kW)
30 (30kW*)
34 (35kW)
50 (50kW*)
70 (70kW*)
min
5
0 (OFF)
1 (Instantanee)
2 (Neutilizat)
3 (boiler extern cu termostat)
4 (boiler extern cu sondă)
5 (boiler integrat DS)
6 (boiler integrat 3S)
°C
40
°C
50
°C
0
0 (OFF)
1 (ON)
2 (PANOU LA DISTANŢĂ + SUPAPE DE ZONĂ)
3 (BAG2)
4 (NEUTILIZAT)
5 (NEUTILIZAT)
6 (BAG2 MIX)
7 (NEUTILIZAT)
8 (NEUTILIZAT)
°C
40
°C
20
g/min
MTN GPL
g/min
12(**) 19(**)
°C
2
°C
2
min
0
min
0
-
0 (NO)
°C
40
°C
20
°C
2
°C
2
0 (OFF)
1 (AUTO)
0 (OFF)
1 (AUTO)
0 (OFF)
1 (AUTO)
-
2.5
0 (OFF)
1 (AUTO)
-
2.5
-
0
-
0
°C
0
°C
0
0 (FOARTE REPEDE)
255 (FOARTE ÎNCET)
DEFAULT
MAX
setat în
fabrică
1
20
20
5
6
60
80
60
85
80
10
5
1
80
80
39
20
MTN GPL
MAX
60(**) 59(**)
MIN
10
6
10
6
20
15
20
5
1 (DA)
0
80
45
39
25
10
3
10
3
1
1
1
1
1
40
20
1
40
10
0
1
1
0
1
0
4
10
6
10
6
20
PARAM
setaţi
de SAT