4.4
Parameter programming
This boiler is fitted with the latest type of electronic cards, allowing you
to set/modify the machine operating parameters and thereby offering
a more personalised configuration to meet the various system and/
or user needs.
The programmable parameters are the ones indicated in the table.
The parameter programming operations must be carried out
with the boiler in the OFF position. To do this, press the
until you see "ENERGY FOR LIFE" on the display.
During the parameter modification operations, the
acts as an ENTER key (Confirm), while the
ESC key (Exit).
If no confirmation is given within 10 seconds, the value is not
stored and the previous one is indicated again.
Setting the password
The programming of the parameters is accessed by pressing the
key and then pressing the
PROG appears on the display followed by CODE.
Press the ENTER key to confirm.
Enter the programming access code to the parameters editing
functions rotating the encoder A until the necessary value is obtained.
Confirm the programming code by pressing the ENTER key.
The programming access password is located inside the command
panel.
Modifying the parameters
- Turn the encoder A to scroll the two digit codes of the parameters
indicated in the table.
Identify the parameter you want to modify in the following way:
- press the ENTER key to be able to modify the parameter value.
- the previously set value will flash when the ENTER key is pressed
- turn the encoder A to the desired value
- confirm the new value by pressing ENTER. The digits will stop
flashing
- quit by pressing ESCAPE
The boiler will switch off, press the
H
I
key acts as an
key for 3 seconds.
key to restore the operation.
ESCAPE
key
key
ENGLISH
ENTER
A
11

Publicité