INSTALLATION MANUAL
1 -
WARNINGS AND SAFETY
After removing the packaging, check the integrity and
completeness of the supply and, otherwise, contact the Riello
Agency that sold the boiler.
The Family Aqua Condens 3.5 BIS boiler must be installed by
a qualified company in accordance with the regulations in force,
at the end of the installation process, must issue the owner with
a declaration of conformity certifying that the installation has
been performed according to the best working practices and
in observance of applicable legislation and of the indications
provided by Riello in the present instructions booklet.
The installer must instruct the user about the operation of the
appliance and about essential safety regulations.
When carrying out routine maintenance, it is always
recommended to check the consumption level of the sacrificial
anode.
The boiler must be used for the use planned by Riello for
which it was designed. Riello declines all contractual and non-
contractual liability for injury to persons or animals or damage
to property deriving from errors made during installation,
adjustment and maintenance and from improper use.
In the event of a water leakage, shut off the water supply and
promptly contact the Riello Technical Assistance Centre or
other professionally qualified personnel.
From time to time, check the
display; this symbol indicates an incorrect charge pressure.
Otherwise, refer to paragraph "Smart system filling".
Not using the boiler for an extended period of time involves the
execution of at least the following operations:
- turn the main appliance switch and the main system switch
to "off"
- close the fuel and water taps of the heating system
- drain the heating and domestic hot water circuits if there is a
risk of freezing.
The boiler maintenance must be carried out at least once a
year.
This booklet and that of the User are an integral part of the
appliance and therefore should be carefully preserved and
should always accompany the boiler even when it is sold to
another owner or user or when transferred to another system.
In case of loss or damage, please contact your local Riello
Technical Assistance Service for a new copy.
The boiler is constructed so as to protect both the user and
the installer from any accidents. After each intervention on the
product, pay special attention to the electrical connections,
especially the stripped parts of the wires, which must not
protrude from the terminal board in any way.
At the end of its life, the product should be not be disposed of
as solid urban waste, but rather it should be handed over to a
differentiated waste collection centre.
Dispose of all the packaging materials in the suitable containers
at the corresponding collection centres.
When disposing of waste, be careful not to harm human health
or employ procedures or methods which may damage the
environment.
Remember that the use of products requiring fuels, electricity and
water necessitates the respect of certain basic safety rules such as:
It is forbidden for children and unassisted unskilled people to
use the boiler.
icon does not light up on the
It is forbidden to activate electric devices or appliances such as
switches, household appliances and so on if you notice a smell
of fuel or unburnt fuel. In this case:
- ventilate the room by opening the doors and windows
- close the fuel shut-off device
- promptly call the Riello Technical Assistance Service or
professionally qualified personnel.
It is forbidden to touch the boiler while barefoot or if parts of
your body are wet.
It is forbidden to carry out any cleaning operations before
disconnecting the boiler from the electricity supply; to do this,
turn the main system switch to "OFF".
It is forbidden to modify safety and adjustment devices without
the boiler manufacturer's permission and relative instructions.
It is forbidden to pull, detach or twist the electric cables that
emerge from the boiler, even if the boiler itself is disconnected
from the mains supply.
It is forbidden to plug or reduce the size of any openings used
for airing the installation area.
It is forbidden to leave flammable containers and substances in
the room where the boiler is installed.
It is forbidden to disperse and leave packaging material within
children's reach as it may be a potential source of hazard.
It is forbidden to obstruct the condensate outlet.
2 -
DESCRIPTION
Family Aqua Condens 3.5 BIS is a wall-hung condensing boiler,
with premix burner and low emission of pollutants for heating and for
the production of DHW use and has a 60 litres steel storage tank.
This is an electronically controlled boilers with automatic ignition,
ionisation flame check and with proportional control system of the
gas and air flows, both in heating and DHW.
It uses an aluminium alloy boiler body, has a sealed combustion
chamber and, based on the gas discharge accessory used, is
classified in categories B23P, B53P, C13-C13x, C23, C33-C33x,
C43-C43x, C53-C53x, C83-C83xC93C93x. The switching of the
heating and DHW modes is performed via a three-way electric
valve which set on DHW when in the rest position. To guarantee the
correct water output in the exchanger, the boiler is equipped with an
automatic by-pass.
it is also equipped with:
- Circulator with variable speed (PWM= Pulse-Width Modulation)
- Modulation 1-10, the boiler can automatically modulate the output
power in a maximum and minimum range (see technical data)
- Range Rated - this means the boiler is equipped with a device
that adapts it to the heat requirements of the system, so the boiler
output can be adjusted according to the energy needs of the
building
- Semi-automatic heating system filling device
- Microprocessor management and control with self-diagnostics
displayed by means of a display
- Circulator anti-blocking
- First-level antifreeze (suitable for indoor installations)
- Premix combustion system which ensures a constant air-gas ratio
- Ambient thermostat or programmable timer or local valve
prearrangement.
- external probe that enables the climate control function
- Prepared for limit thermostat on reduced temperature systems
- Anti-legionella: Legionella is a disease that can be contracted
by inhaling small droplets of water (aerosols) which contain the
Legionella bacteria (bacteria occurs naturally in lakes and rivers
ENGLISH
3

Publicité