- press the heating temperature adjustment key
will show the number corresponding to the set comfort level (fac-
tory setting)
- rotate the encoder A to raise or lower the chosen comfort level
(the two digits B will show the number +1, +2, etc. or -1, -2, etc.,
corresponding to the chosen level).
The segment lit up in the heating comet will rise or fall.
The correction range is between - 5 and + 5 comfort levels.
These corrections are very important in the mid-seasons, when the
value calculated by the curve may be too low and the room heating
time therefore too long. When 3 seconds have passed since the last
modification, the value is automatically stored and the display again
shows the value measured instantaneously by the probe.
F -
To adjust the temperature of the domestic hot water, just press the
key.
. The two digits
The two digits will no longer show the temperature measured instan-
taneously by the probe, but the temperature (flashing) previously set.
By rotating the encoder A, you can raise or lower the temperature.
When 3 seconds have passed since the last modification, the value
is automatically stored and the display again shows the value meas-
ured instantaneously by the probe.
B
The set temperature is displayed both numerically (e.g.. 40° C) and
as illumination of the comet.
A
The display will show the storage tank temperature only when the
domestic water icon is flashing.
The display indicates the storage tank temperature if there is a heat
request from the domestic water system. At the end of a storage tank
heating cycle therefore, the tap icon on the domestic water comet
switches off and the display shows the outlet temperature (that may
fall well below the temperature of the storage tank domestic hot water).
G - Temporary switch-off
In the event of a temporary absence, weekends, short journeys and
so on:
- Press
LIFE" and the anti-freeze icon.
Adjusting the domestic hot water
temperature
. The display will visualise the words "ENERGY FOR
ENGLISH
A
23