Prepare
and clean
lock pocket
Fasten the multi-point
lock 319
Fasten the appropriate
striking plate
EN
44
Installation
Caution!
Risk of injury due to sharp edges and chips: There is a risk of injury due to sharp edges and chips from
drilling or other cutting work. Take particular care to protect your eyes with suitable protective goggles.
Preparation for mounting
Caution!
Unsuitable doors reduce personal safety and intrusion protection: Only approved and technically cor-
rect doors are suitable for installation of the multi-point lock 319. Prior to the installation of the multi-point
lock 319, the door must be checked to ensure that it is attached properly and is not warped. The door
must be approved for use of the multi-point lock 319.
1
Create the lock pocket at a suitable mounting position in the door leaf.
2
Finish the holes for the fixing screws (Pic. 17).
3
Finish the holes for the lock fittings.
4
Clean the lock pocket and all holes by blowing them out or vacuuming.
Install the multi-point lock 319
1
Fasten the multi-point lock 319 in the lock pocket.
2
Fasten the lock fittings.
3
Check the multi-point lock 319 for ease of movement.
Once the striking plate is mounted, the multi-point lock 319 is ready for use.
Mounting the striking plate
1
Finish the striking plate pocket and all holes or finish a customer-provided striking plate ("Production
of customer-provided striking plates", page 48).
2
Clean the striking plate pocket and all holes by blowing them out or vacuuming.
3
Screw in the appropriate locking plate for the multi-point lock 319 to be screwed in.
4
Check the multi-point lock 319 for ease of movement.
The multi-point lock 319 is ready for operation.
Installation