Installing Fittings And Locking Cylinders; Testing The Multi-Point Lock 319 - Assa Abloy effeff 319 Notice D'installation Et De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Fasten the locking
cylinder with the
cylinder fixing screw
Check for complete
functionality
Pic. 7 :
No transverse shear
stress on the bolt after
installation
Installation

Installing fittings and locking cylinders

1
Install the fittings.
2
Insert the locking cylinder, and ensure that the locking cylinder nose is in the centre position (Pic. 9).
3
Fix the locking cylinder into place with the fixing screw.
 The multi-point lock 319 is completely installed.

Testing the multi-point lock 319

1
Test all functions of the multi-point lock 319.
2
Check whether the latch and control latch of the lock are pushed back by the same impact edge.
3
Check whether all bolts can freely extend and retract without transverse shear stress after installation
(Pic. 7).
 The multi-point lock 319 is completely installed and has been tested for functionality.
Striking plate
F
= 0
Q
N
min. 2
F
= 0
Q
N
Face plate
EN
45