Installation Instructions
Pneumatic connection
WARNING: PNEUMATIC INSTALLATION MUST BE
PERFORMED ONLY BY LICENSED PERSONNEL.
The machine requires an air pressure of 8 to 12 bar
(110-170 psi), as marked on the plate of the machine
and on a sticker attached to the cabinet next to the
air inlet.
Ensure that the line pressure is within the limits
required by the machine.
If the air pressure is lower than the minimum required
of 8 bar (110psi) the lifting power and bead pusher
power may be insuffi cient for certain tires.
The rubber hose that connects the machine to the
compressed air supply line (1, Fig.iii-5) should have
a diameter of 8 mm. It should also be a suitable length,
i.e. it should not be too long as it will get in the way and
it should not be too short as this will cause tension.
Even though the machine itself has a filter, it is
advisable to fi t a fi lter on the compressed air feed line
to reduce the quantity of air present in the line.
WARNING: MAKE SURE THAT THE COMPRESSED
AIR SUPPLY LINE DOES NOT EXCEED 12 BARS
WARNING: THE HOSE THAT CONNECTS THE
MACHINE TO THE COMPRESSED AIR SUPPLY
LINE SHOULD BE ABLE TO STAND A MAXIMUM
OPERATING PRESSURE OF 12 BARS
WARNING: BEFORE CONNECTING THE MACHINE
TO THE COMPRESSED AIR SUPPLY MAKE
SURE THAT NOTHING IS IN THE WORK AREA
AND THAT ANYONE STANDING NEAR THE
MACHINE MOVES AWAY
After ensuring all the above proceed as follows:
• Check the oil level in the lubricator (2, Fig.iii-5). Top
up if necessary (see Maintenance chapter).
• Connect the machine to the compressed air supply
line (1, Fig.iii-5).
• Check that oil is fed out correctly from the lubricator
(see Maintenance chapter).