AREAS OF
APPLICATION
Submersible pumps in the MultiFree
range are suitable for pumping waste-
water in municipal and industrial
pumping stations, and in rainwater re-
tention tanks. The smallest models also
perform well in disaster control appli-
cations.
MultiFree pumps are favoured for use
with:
- wastewater containing fibres that
form bundles
- wastewater containing solids (with-
out stones)
- abrasive wastewater
- wastewater containing gas or air
pockets
- mixed wastewater
- untreated water
- raw sludge
- surface water and rainwater
The submersible pumps are supplied
without explosion protection or with ex-
plosion protection.
When using the pumps, the relevant
national laws, regulations and stipula-
tions must be adhered to, for example:
∙ Installation of lowvoltage systems
(e.g., VDE 0100 in Germany)
∙ Safety
and
working
(e.g., BetrSichV and BGR 500 in Ger-
many)
∙ Safety
in
wastewater
(e.g., GUV-V C5, GUV-R 104, GUV-
R 126 in Germany)
∙ Electrical systems and operating re-
sources (e.g., GUV-VA3 in Germany)
∙ Explosion protection
EN 60079-0:2012, EN 60079-1:2007,
EN 60079-14:2007, EN 60079-
14:2007 and EN 1127-1:2011
For non-standard utilisation conditions
in areas subject to explosion hazards,
please ask the local authority respon-
sible.
In Germany, this would be, for example,
the Trade Supervisory Centre (Gewer-
beaufsicht), the Technical Inspection
Agency (TÜV), the building authority
(Bauamt) or professional organisation
(Berufsgenossenschaft).
The installation and operation of this
equipment is regulated by the ordinance
concerning the protection of health and
safety in the provision of work equipment
and its use at work, concerning safety
when operating installations subject to
monitoring, and concerning the organi-
sation of industrial health and safety at
work, (Betriebssicherheitsverordnung),
Article 1.
Where no explosion protection is stipu-
lated for the pumping of foul wastewa-
ter at the installation location, pumps
without explosion protection may also
be used.
Modes of operation
with the pumped medium at a tem-
perature of 40°C:
Motor submersed: continuous opera-
tion S1
Motor emerged: short duration opera-
tion S2; see "Technical Data"
Motor emerged: intermittent operation
S3; see "Technical Data"
The submersible pump is frost-resist-
ant down to -20°C when stored in dry
conditions. When installed, however,
it must not be allowed to freeze in the
water.
Transport
The pump must never be lifted
by the power supply cable! The
pump should only be lowered by
using a chain or a rope.
ELECTRICAL
materials
CONNECTION
systems
By using our controls, you can be sure
that the requirements of the EU type-
testing certificate are met.
Only qualified electricians may
carry out electrical works to
the pump or the controls.
The standards applicable in each case
(e.g. EN), the country-specific regula-
tions (e.g. VDE in Germany), and the
regulations of the local supply network
operator must be observed.
ATTENTION! Never lay the end of ca-
bles in water! Penetrating water may
cause malfunctions.
ENGLISH
Δ-Circuitry for low voltage
Y-Circuitry for high voltage
Y-Circuitry for high voltage (CW2)
Alterations to the circuitry are to be
made using crimp connectors (X) be-
tween the coni plug connection (Y) and
the built-in motor. The new crimp con-
nection must be professionally made.
Only slow-blow fuses or automatic fus-
es with C or D characteristics are to be
used as pre-fuses for the pump. Nec-
essary fuse protection for direct on-line
start: 16 A, and for star-delta start 20 A
(CW2).
The pump must be protected via an
overload trip. Setting for direct on-line
start = nominal current, and for star-
delta start = nominal current x 0.58.
If the protective device has been trig-
gered, the cause of the malfunction
must be eliminated before switching on
again.