Air Filter, Engine - Stiga PARK Série Mode D'emploi

Masquer les pouces Voir aussi pour STIGA PARK Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 70
EN
4. Test drive the machine straight forwards and
check that the steering wheel is not off centre.
5. If the steering wheel is off centre, undo one nut
and tighten the other.
Do not over-tighten the steering chains. This will
cause the steering to become heavy and will in-
crease wear on the steering chains.
5.9 BATTERY
If acid comes into contact with the eyes
or skin, this can cause serious injuries.
If any part of the body has come into
contact with acid, rinse immediately
with copious amounts of water and seek
medical assistance as soon as possible.
The battery is a valve-regulated battery with 12 V
nominal voltage. The battery fluid does not need to
and cannot be checked or topped up. The only
maintenance that is required is charging, for exam-
ple after extended storage.
The battery must be fully charged be-
fore being used for the first time. The
battery must always be stored fully
charged. If the battery is stored while
discharged, serious damage will occur.
5.9.1 Charging with the engine
The battery can be charged using the engine's gen-
erator as follows:
1. Install the battery in the machine as shown be-
low.
2. Place the machine outdoors or install an extrac-
tion device for the exhaust fumes.
3. Start the engine according to the instructions in
the user guide.
4. Allow the engine to run continuously for 45
minutes.
5. Stop the engine. The battery will now be fully
charged.
5.9.2 Charging using battery charger
When charging using a battery charger, a battery
charger with constant voltage must be used.
Contact your dealer to purchase a battery charger
with constant voltage.
The battery can be damaged if a standard type bat-
tery charger is used.
5.9.3 Removal/Installation
The battery is placed under the engine casing. Dur-
ing removal/installation, the following applies re-
garding connection of the cables:
• During removal. First disconnect the black ca-
ble from the battery's negative terminal (-).
Then disconnect the red cable from the battery's
positive terminal (-).
• During installation. First connect the red cable
to the battery's positive terminal (+). Then con-
68
ENGLISH
nect the black cable to the battery's negative ter-
minal (-).
If the cables are disconnected/connect-
ed in the wrong order, there is a risk of
a short-circuit and damage to the bat-
tery.
If the cables are interchanged, the gen-
erator and the battery will be damaged.
Tighten the cables securely. Loose ca-
bles can cause a fire.
The engine must never be driven with
the battery disconnected. There is a risk
of serious damage to the generator and
the electrical system.
5.9.4 Cleaning
If the battery terminals are coated with oxide, they
should be cleaned. Clean the battery terminals with
a wire brush and lubricate them with terminal
grease.

5.10 AIR FILTER, ENGINE

5.10.1 Air filter (Plus, Residence, Prestige,
Ranger)
The air filter (paper filter) must be cleaned/re-
placed after 100 hours of operation.
NOTE! The filters should be cleaned/replaced
more often if the machine operates on dusty
ground.
Remove/install the air filters as follows.
1. Clean carefully around the air filter housing.
2. Dismantle the air filter cover (13:R) by remov-
ing the two screws.
3. Dismantle the paper filter insert (13:S). Make
sure that no dirt gets into the carburettor. Clean
the air filter housing.
4. Clean the paper filter by tapping it gently
against a flat surface. If the filter is very dirty,
replace it.
5. Assemble in the reverse order.
Compressed air or petroleum-based solvents such
as kerosene may not be used for cleaning the paper
filter insert. This will damage the filter.
Do not use compressed air for cleaning the paper
filter insert. The paper filter insert must not be
oiled.
5.10.2 Air filter (Ranger Svan, Royal)
Clean the air filter every 3 months or after every 50
hours of operation, whichever comes first.
Clean the paper filter insert once a year or after
every 200 hours of operation, whichever comes
first.
Note! Both filters should be cleaned more often if
the machine operates on dusty ground.
1. Remove the protective cover of the air filter
(fig. 14).
Original instructions for use

Publicité

Table des Matières
loading

Table des Matières