Fitting The Gate Section Mounting Bracket - SOMFY HOME MOTION IXENGO L Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
If dimension B is excessive:
• Use adjustable mounts (9014609 or 9014610) that allow setting the following four or eight values of Z (in cases where
you need to reduce or increase the value of Z):
P1: Z = 78 mm
P9: Z = 203 mm
P2: Z = 90 mm
P10: Z = 215 mm
P3: Z = 102 mm
P11: Z = 227 mm
P4: Z = 114 mm
P12: Z = 239 mm
P5: Z = 155 mm
P6: Z = 167 mm
P7: Z = 179 mm
P8: Z = 191 mm
Adjustable mount installation position
Left
Right
• Or move the gate hinges so as to reduce distance B (refer to "Specific Installations").
• Attach the mounting bracket P.
Fitting the post mounting bracket
Example
When the desired opening angle is 90°:
• Measure dimension X = 90 mm.
• Calculate dimension B = X + Z = 90 + 110 = 200 mm.
• Apply dimension B = 200 to the table and use a dimension A = 190 for a 90° opening.

Fitting the gate section mounting bracket

Important: On the gate section, measure dimension c (805 mm), the length between the two mounting bracket centres.
Mark the mounting axis for the gate section mounting bracket.
[1] Unlock motor drive rod E.
[2] Temporarily fit the motor drive unit on its mount P.
[3] Fit the gate section mounting bracket F onto the drive rod E.
[4] Check that the motor drive unit E is horizontally aligned using a spirit level.
[5] Attach the gate section mounting bracket F.
tip for respecting dimension c:
Unlock the motor and manually move the knob on the cylinder so that the edge of
the knob is approximately 65 mm from the edge of the cylinder (see the illustration
opposite).
6
P1
P2
P3
P4
Z
*
P5
P6
P7
P8
P9
P10
P11
P12
Z
*
* Not supplied / non fournis