Bourgeat NAVTHERM Série Notice D'utilisation Et D'entretien page 14

Systeme de distribution de repas en liaison froide
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
y Reheating end time or service time :
- LH side displays 4 blink. Set hours with buttons 9 and 10.
- confirm with switch 8. RH side displays blink. Set minutes with buttons 9 and 10.
- confirm with switch 8.
y Reheating duration :
- displays 7 blink. Set duration with buttons 9 and 10.
- confirm with switch 8.
- «P1», «P2» or «P3» appear on displays 3.
- In order to modify another programme, proceed as above.
Deactivation of a programme : the programme is deactivated by depressing switch 5. «OFF» appears on displays 4.
Activation of a deactivated programme : the programme is activated with the previously set values when depressing switch
5.
- Should all programmes be deactivated, the terminal only operates in cold.
- If no button is depressed for 10 seconds, programming mode is quit.
When a programme is activated, the indication P1, P2 or P3 is displayed on the displays 3.
LOCKING THE PARAMETER ACCESS
Access to all parameters can be locked using a password. If locking is activated, the password is required to change the
time, programmes and access to machine parameters.
y To activate the password : press keys 8 and 10 simultaneously.
Press key 8 twice until LOCK appears on the central display. Use keys 9 and 10 to select the password (from 01 to 99).
Press key 8 to validate or wait for 10 seconds. The password is activated.
y Removing the lock : Apply the same sequence as for locking and define 00 as password.
POWER FAILURE MANAGEMENT
In case of power failure while the terminal is operating, the trolley may be disconnected (the electromagnets are no longer
supplied). In this case, when power is restored, an alarm sounds until the trolley is reconnected, and the cycle in progress
is resumed.
The card has a 'dry' contact to control an outside alarm.
Cable output will be ensured through a cable gland in the pre-cut hole below the power cable.
Caution! Installation must be performed with the terminal disconnected electrically and by skilled staff.
- 14 -
Imax contact : 8A
U 230V
Pre-cut

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

881800881803881900881903880002

Table des Matières