Filter; Drain Condensation - probst STONEMAGNET SM-600-GREENLINE Instructions D'emploi

Masquer les pouces Voir aussi pour STONEMAGNET SM-600-GREENLINE:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING
► Only apply suction to the load. Do not lift.
1.
Wait until a vacuum of approx. -0.6 bar is reached.
2.
Turn off vacuum pump. The vacuum should not drop by more than 0.1 bar within 5 minutes.
3.
Release the load after inspection (see section 0).
Rectify any faults before starting the device. Should faults occur during operation, switch off the device and rectify the
faults.

Filter

Inspect both dirt filters at least once a week. Replace filters if they are extremely dirty.
Procedure:
1.
Open unit cover.
2.
Disconnect hose clamp and remove filter.
3.
Insert new filter and attach with hose clamp.
4. Close the unit cover again.
5. Check airtightness (see above).

Drain condensation

Vacuum generation produces condensation due to humidity. Condensation must be drained at least once a day. Inspect
sight glass (18) as necessary.
Procedure:
1.
Open blow off valve (item 17) and drain condensation.
2.
Close the drain valve.
40/43
Danger from falling load in the event of vacuum failure
The load may come loose and fall off during inspection.
18
17