3.5 Fitting the end limit brackets - Fig. 11
[1]. Manually move the gate to the open position.
[2]. Position a bracket onto the rack so that it activates the motor end limit
contact.
[3]. Screw the bracket onto the rack.
[4]. Manually move the gate to the closed position, then repeat steps 2 and 3 to
fit the second bracket to the rack.
3.6 Connecting the safety edge - Fig. 12
For the installation to be compliant with the standards in force, an active
safety edge must be connected.
3.7 Connecting to the power supply - Fig. 13
To connect the motor to the power supply, use a 3x1.5 mm² cable for use
outdoors (minimum type H07RN-F).
Connect the neutral (N) to terminal 1 of the motor.
Connect the live (L) to terminal 2 on the motor.
Connect the earth wire to the earth terminal on the base of the motor.
The earth wire must always be longer than the live and neutral to ensure
that it is the last to be disconnected if the connector is pulled out.
The cable clamps supplied must be used.
For all low-voltage cables, ensure that they can withstand traction of
100 N. Check that the conductors have not moved when this traction is
applied.
3.8 Direction of rotation - Fig. 14
Set dipswitch no. 3 to ON if the motor is installed on the left or OFF of the motor
is on the right.
3.9 Re-engaging the motorisation - Fig. 15
[1]. Place the gate approximately 1 m from its closed position.
[2]. Turn the release handle to the left.
[3]. Move the gate manually until the drive mechanism re-locks.
[4]. Turn the key a quarter of a turn to the right.
Switch on the power to the installation before commissioning.

4 - QUICK COMMISSIONING

4.1 Memorising the remote controls
To memorise a 2- or 4-button remote control - Fig. 16
[1]. Press the PROG button on the control unit for 2 seconds. The red indicator
light will come on.
[2]. Press a channel on the remote control to which the motorisation will be
linked within 2 minutes. The red indicator light flashes; the remote control
has been memorised.
If this procedure is carried out using a channel which has already been
memorised, this channel will be cleared.
To add other 2- or 4-button remote controls:
Repeat the above procedure.
To add a 3-button remote control - Fig. 17
[1]. Press the PROG button on the control unit for 2 seconds. The red indicator
light will come on.
[2]. Press the PROG button on the back of the Telis; this must be done within
2 minutes. The red indicator light flashes; the remote control has been
memorised.
To exit programming mode without programming a remote
control:
Press the PROG button of the control unit briefly.
4.2 Programming the gate travel - Fig. 18
The motor operating times at normal speed and for the slowdown phase can be
programmed.
Programming requires a single, full opening movement. Operation is the same
Copyright © 2015 Somfy SAS. All rights reserved.
during opening and closing (same slowdown zone).
Programming the gate travel
When programming, the gate should be open (approximately 1 m) and
the motor locked.
[1]. Press the SET button for 2 seconds.
The POWER and SET indicators flash.
[2]. Press the button on a memorised remote control to start programming.
The gate will close then open.
[3]. When the gate reaches the position where a slowdown is required, press
the button on the memorised remote control.
The gate completes its opening movement at a reduced speed.
Note: Do not complete this step if no slowdown is required.
Programming is complete. The POWER indicator is lit steady.
The slowdown position during closing will then be similar to that set for
opening (e.g. 20 cm before the end of travel).
The gate must not encounter any point of resistance in the slowdown
zone. If the gate stops moving before opening or closing fully, reduce or
remove the slowdown zone
During programming, pressing the SET button for 2 seconds will interrupt
programming. During programming, the safety inputs are active.
At the end of installation, it is essential to check that the obstacle detection
complies with appendix A of standard EN 12 453.
AT THIS STAGE IN THE INSTALLATION, THE MOTORISATION IS
OPERATIONAL.

5 - OPERATING TEST

5.1 Using the remote controls - Fig. 19
Default sequential operating mode.
5.2 Operation of the photoelectric cells
Cells obscured when closing = the gate stops and reopens fully.
Obstruction of the cells during opening = the gate stops.
5.3 Operation of the safety edge
Obstacle detected when opening/closing = stop + partial reversal.
5.4 Specific operation
See the user booklet.
5.5 User training
All users must be trained on how to safely use this motorised gate (standard use
and unlocking principle) and on the mandatory periodic checks.
WARNING
5