EN
5) Tighten the end stop definitively using a long Allen key for greater
torque when tightening the end stop screws (16 Nm).
A
B
D
E
6) Install the end stop covers: screw the lower cover (with holes) (18b),
holding the sha while performing this operation, then screw in the
upper cover (18a).
18a
2
1
18b
7) Permanently secure the gate leaf bracket using the central mounting
hole.

7. ELECTRICAL CONNECTIONS

7.1. Cable guide fitting
Fit the cable guides on the two motors.
7

7.2. Connecting the motors

Motor M1 actuates the gate leaf that opens first and closes last, and opens
C
for pedestrian access.
To connect the motors to the electronics, refer to the instructions
in the installation manual of the Axovia Control Box 3S.
F
M1 is to the le

7.3. Connecting the motor earth

Connect the earth wire of the Axovia Control Box 3S (terminal 3 or 4) to the
earth connector in the motor.

7.4. Locking the arms

1) Close the two gate leaves and lock the arms by pressing them.
2) Turn the motor locking handles to the locked position .

8. COMMISSIONING

For the commissioning procedure, refer to the instructions in the installa-
tion manual of the Axovia Control Box 3S.