ahlmann AS 45 Manuel De L'opérateur page 226

Chargeuse pivotante
Table des Matières

Publicité

Malfunction
Swivel mechanism
does not swivel
Stabilizer fails
Stabilizer fails when Non-return valve in the
bucket arm is low-
ered in the swiveled
position
Defects in the drive
and working
hydraulics
Defects in the
braking system
S45C
GB
Possible cause
Block wedge blocks
swiveling (1-2/arrow)
Pressure relief valve in
the control valve is open
The stop valve's connec-
tion in the frame under the the direction of travel;
revolving seat is jammed
pressure line is open
The filter is clogged
Lack of oil in the hydraulic
oil reservoir
Electrical connections to
the axial piston pump are the wiring diagram or
loose, disconnected or
oxydized
Parking brake does not
hold the loader
Service brake works
irregularly
Remedy
Remove block wedge
and place it in it holder
Completely dismantle
and clean the pressure
relief valve; readjust *
Bring the bucket arm in
make it move freely
Bring the bucket arm in
the direction of travel;
remove and clean the
non-return valve; if
necessary, replace *
Replace filter insert
Refill oil
Connect according to
clean
Check settings; if
necessary, adjust or
replace the brake
linings *
Check storage
pressure *
Check connection
elements between dual
brake pedal and
pressure release valve
9-2

Publicité

Table des Matières
loading

Table des Matières