4.7 ACTUATOR RELAY MODULE ART. 1256

Intelligent device for controlling a 24 AC/DC 10A relay (fitted) for general uses. Fit a max. of 10 actuator relay modules Art. 1256 on the whole system.
1.
JP3
2
1
JP2
1
JP1
JP1
JP1

4.7.2 Functions

Art. 1256 offers the following functions, depending on the position of jumper JP1:
JP1
• External unit lighting control
• Activation function on Actuator pushbutton.
• Activation function on Actuator with code pushbutton
External unit lighting control
JP1
The relay is operated by closing the C.NO. contact in response to a call from an external unit to any address, on internal
ignition from a video entry phone (e.g. to automatically activate lights, CCTV alarm contacts, etc.). The relay closure time can
be programmed using a S1 DIP-switch in accordance with the table B.
JP1
Activation function on Actuator pushbutton
JP1
The relay is operated by closing the C.NO. contact in response to a Generic actuator call from a video entry phone. The relay
closure time can be programmed using a S1 DIP-switch in accordance with table B. All Art. 1256 modules set for use with this
function are activated simultaneously when the pushbutton on the internal unit is pressed.
JP1
Activation function on Actuator with code pushbutton
JP1
The relay is operated by closing the C.NO. contact if the pushbutton pressed on the video entry phone has been programmed
to send the actuator call with the code of the actuator. The closure time of the relay is fixed at 2 sec. To set the user code by
means of a S1 DIP-switch, see page
DIP switches sur ON
Relay closing time
The relay for Art. 1256 operates in BISTABLE mode, changing its status at every command; if the power supply is cut off, it returns
to the C.NO. position and remains there, even after the power is restored. Bistable mode is available for products with a revision index
equal to or greater than 003.
JP3
2
1
2.
JP3
2
1
2
JP2
1
3.
4.
2
JP2
1
5.
6.
32 "TAB. A"
TABLE B: PROGRAMMING RELAY CLOSURE TIME
(For external unit light function/stair light function, activation function on actuator pushbutton)
TOUS
1
1''

4.7.1 Parts description

1. JP4
2. JP3
3. JP2
To use the actuator relay module with kit HFX-9000M
„ Move jumper JP2 to position 2
„ Move jumper JP3 to position 2
„ Move jumper JP4 to position 2
JP1
4. S1 DIP switch for different setting
5. JP1 for functions setting
6. Terminal block for system connection:
NC
COM
JP1
NO
L L
~+, ~-
JP1
JP1
JP1
JP1
JP1
JP1
.
JP1
2
3
4
2''
4''
8''
JP3
2
1
2
JP2
1
relay N.C. contact
relay COM contact
relay NO contact
BUS line input
power supply input terminals
5
6
7
16''
32''
1' 5''
JP1
JP1
JP1
8
2' 10''