Total Open/Close Programming; Pedestrian Open/Close Programming - Erreka VIVO-M201 Guide Rapide D'installation Et Programmation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5
Total opening radio code programming (with RSD receiver only)
If a receiver other than RSD is used,
see the corresponding instructions.
1 Connect
the
electrical
supply and close the leaves, keeping
PUL1 pressed down.
2 Select the code in the transmitter.
If a single operator is used (A1), the three strokes of ST1 corresponding to step 6 must be
carried out quickly in order to keep the corresponding A2 times to a minimum. Similarly,
the three strokes of ST1 corresponding to steps 7, 8 and 9 must be carried out quickly.
1 Connect the electrical
power supply and close the
leaves,
keeping
PUL1
pressed down.
2 Place DIP1 in ON, DIP2 in
ON, DIP5 in ON (only with
electrolock), DIP8 in ON
(soft stop)*.
S176B
DL3 lights up (programming
enabled).
3 Press
ST1
to
start
opening leaf 1.
*: If hydraulic operators with absorbers are used, soft stop is carried out mechanically by the operator (DIP8 = OFF)
This is carried out in the same way as total open/close
programming, with the following differences:
3 Place the DIPs as shown in the
figure (DIP1=ON, DIP4=ON). DL3
lights up to show programming mode
enabled.
power
4 Press the button of the required
channel.
DL2
programming is complete.

Total open/close programming

4 Press ST1 to start soft
stop (with DIP8=ON only).
5 Press
ST1
to
finish
opening.
6 Carry
out
the
same
sequence with leaf 2.

Pedestrian open/close programming

5 Place DIP1 and DIP4 in OFF.
DL3 remains off.
R176B
6 Disconnect and reconnect the
electrical power supply.
flashes
to
show
Programming is carried out in the
same way, using DIP6 instead of DIP4.
7 Press ST1 to start closing
leaf 2
8 Press ST1 to start soft
stop (with DIP8=ON only).
9 Press
ST1
to
finish
closing.
• DIP1 and DIP3 are used instead of DIP1 and DIP2
• Carried out only with leaf 1
• ST2 is used instead of ST1
R176K
Pedestrian opening radio
code
10 Carry out the same
sequence with leaf 1.
11 Place DIP1 and DIP2 in
OFF. DL3 remains off.
S176K
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vivo-m201 m

Table des Matières