INSTALLATION
1
TOOLS AND MATERIALS
Screwdrivers
Fixed wrenches (13 mm)
2.5 mm and 4 mm Allen keys
Marker pencil
Spirit level
Tape measure
2
INITIAL CONDITIONS AND CHECKS
Initial conditions of the gate
Check that the size of the gate is within the
admissible range of the actuator (see the
technical characteristics of the actuator).
If the gate to be automated has a passage gate,
use a safety device to prevent the actuator
from operating with the passage gate open.
The gate must have a closing stopper. When
installing an articulated arm, it is necessary to use
the opening and closing stopper.
Environmental conditions
This device is not suitable for installation in
inflammable or explosive environments.
Electrical power supply installation
The electrical connections shall be made in line
with the instructions in the control panel
manual.
30
Installation Manual
Electric drill and broaches
Use the electrical drill in line with the use
instructions.
Screws to attach the actuator bracket and the arm
bracket
The gate must be easy to manipulate manually,
namely:
• It must be balanced, in order to ensure the effort
made by the motor is minimum.
• There should be no stiffness throughout its travel.
Do not install the actuator in a gate which does
not work correctly in manual operation, as this
may lead to accidents. Repair the gate before
installing.
Check that the admissible environmental
temperature range for the actuator is suitable
for the location.
The electrical cable section is indicated in: "Fig. 1
Elements of the complete installation" on page 27.