This control board is factory set to use a two-channel receiver (e.g. IRRE2). This factory setting is modified if an RSD receiver is used and a
permanent code is recorded (decoding through the board, DIP1 + DIP4 or DIP6 = ON). To recover the factory settings, insert the IRRE2 card
and place DIP1 + DIP4 or DIP6 = ON. Then return the DIPs to their previous position.
Total opening radio code programming (with RSD receiver only)
If a receiver other than RSD is used,
see the corresponding instructions.
1 Connect
the
electrical
supply and close the leaf, keeping
PUL1 pressed down.
2 Select the code in the transmitter.
1 Connect the electrical power supply
and close the leaf, keeping PUL1
pressed down.
2 Place DIP1 in ON, DIP2 in ON, DIP5
in ON (only with electrolock), DIP8 in
ON (soft stop)*.
DL3 lights up (programming enabled).
3 Press ST1 to start opening the leaf.
*: If hydraulic operators with absorbers are used, soft stop is carried out mechanically by the operator (DIP8 = OFF)
This is carried out in the same way as total open/close
programming, with the following differences:
Using radio cards
3 Place the DIPs as shown in the
figure (DIP1=ON, DIP4=ON). DL3
lights up to show programming mode
enabled.
power
4 Press the button of the required
channel.
DL2
programming is complete.

Total open/close programming

4 Press ST1 to start soft stop (with
DIP8=ON only).
5 Press ST1 to finish opening (if FCA
is installed, it is not necessary to press
ST1).
6 Press ST1 to start closing the leaf

Pedestrian open/close programming

5 Place DIP1 and DIP4 in OFF.
DL3 remains off.
R175B
6 Disconnect and reconnect the
electrical power supply.
flashes
to
show
Programming is carried out in the
same way, using DIP6 instead of DIP4.
7 Press ST1 to start soft stop (with
DIP8=ON only).
8 Press ST1 to finish closing (if FCC is
installed, it is not necessary to press
ST1).
9 Place DIP1 and DIP2 in OFF. DL3
remains off.
• DIP1 and DIP3 are used instead of DIP1 and DIP2
• ST2 is used instead of ST1
Pedestrian opening radio
code
R175K