Types 2030, 2031, 2031 K
Technical Data
6.2.
Operating conditions
Warning!
danger of bursting from overpressure!
If the device explodes, there is a risk of serious injury, chemical
burns, scalding!
•
Do not exceed the maximum control and medium pressure.
Observe specifications on the rating plate!
•
Observe permitted ambient and media temperature.
6.2.1.
allowable Temperatures
ambient temperature for actuators:
Material
size ø
PA
40 – 125 mm
40 – 80 mm
PPS
100 mm, 125 mm +5 – +90 °C (briefly up to +140 °C)
Table 1:
Ambient temperature for actuators
Medium temperature for housing:
housing material
Stainless steel
PVC (see PT graph)
PVDF (see PT graph)
PP (see PT graph)
Table 2:
Medium temperature for housing
temperature
-10 – +60 °C
+5 – +140 °C
temperature
-10 – +140 °C
-10 – +60 °C
-10 – +120 °C
-10 – +80 °C
Medium temperature for diaphragms:
Material
temperature
EPDM
-10 – 130 °C
PTFE
FKM
-5 – +130 °C
Table 3:
Medium temperature for diaphragms
English
remarks
Steam sterilization up to +150 °C
dry up to +150 °C
otherwise only briefly up to 150 °C
11