Burkert 2030 Manuel D'utilisation page 26

Masquer les pouces Voir aussi pour 2030:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

dn
tightening torques for diaphragms [nm]
epdM / fkM
8
2
15
3.5
20
4
25
5
32
6
40
8
50
12
65
15
Table 9:
Tightening torques for diaphragms
8.3.2.
connection of the control Medium
Control function a:
Connect control medium to lower connection.
Control function B:
Connect control medium to upper connection.
Control function i:
Connect control medium to upper and lower connections.
(see Fig. 6: Pneumatic Connection)
Pressure on the upper connection closes the valve.
Pressure on the lower connection opens the valve.
26
ptfe
2.5
4
4.5
6
8
10
15
20
English
Types 2030, 2031, 2031 K
Installation
Upper control air connection
(for CFB and CFI)
Lower control air connection
(for CFA and CFI)
Fig. 6:
Pneumatic Connection
Control air hose:
Control air hoses of sizes 6/4 mm or 1/4" can be used.
Optionally a control air connection is possible via a G 1/8 thread.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

20312031 k

Table des Matières