10.
MainTenance, cleaning
10.1.
safety instructions
Danger!
risk of injury from high pressure in the equipment!
•
Before loosening the lines and valves, turn off the pressure and
vent the lines.
risk of injury due to electrical shock!
•
Before reaching into the system
and secure to prevent reactivation!
•
Observe applicable accident prevention and safety regulations
for electrical equipment!
Warning!
risk of injury from improper maintenance!
•
Installation may be carried out by authorized technicians only
and with the appropriate tools!
risk of injury from unintentional activation of the system and
an uncontrolled restart!
•
Secure system from unintentional activation.
•
Following maintenance, ensure a controlled restart.
28
, switch off the power supply
English
Types 2030, 2031, 2031 K
Maintenance, Cleaning
10.2.
Maintenance Work
10.2.1.
actuator:
The actuator of the diaphragm valve is maintenance-free provided it
is used according to these operating instructions.
10.2.2.
Wearing parts of the diaphragm
Valve:
Parts which are subject to natural wear:
•
Seals
•
Diaphragm
→
If leaks occur, replace the particular wearing parts with an appro-
priate spare part.
(see Chapter "13. Spare parts").
A bulging PTFE diaphragm may reduce the flow-rate.
10.2.3.
inspection intervals
→
Check diaphragm for wear after maximum 10
Muddy and abrasive media require correspondingly shorter
inspection intervals!
5
switching cycles.