Dismantling the module
Unlatch the upper locking hook by using a screwdriver on the end dismantling-groove.
Remove the block part / module sideways.
Other possible uses of the connecting module, - right-hand -
• As a separation module for special applications when building up several pressure levels in a single
block.
• Additional supply lines for larger valve blocks.
Where necessary, break out the rated break-points of ports 1 and 3.
NOTE
Mounting the valve block
Standard rails
Electrical connection
can be rotated by 180 °
Wall mounting
Standard rail 35 x 15
or 35 x 7,5
EN 50022
Connecting
module
Figure 2: Mounting the valve block
Wall mounting
Fix the module system directly to the wall using M4 screws.
I
, I
NSTALLATION
NITIALISATION AND
Installation
Hang the valve block onto the upper
groove of the standard rail.
Latch the lower clamp into the standard
rail.
Firmly tighten the screws on the clamp.
Dismounting
Loosen the clamping screws (by about
4 revolutions).
Remove the block upwards from the
standard rail.
S
ERVICE
5470 / MP05 - 13