Valve Construction; Valve Operations Of The Type 5470 - Burkert MP05 Instructions De Service

Bloc multiple et profil pneumatique modulaire
Masquer les pouces Voir aussi pour MP05:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

T
D
ECHNICAL
ESCRIPTION

Valve construction

• 3/2 way pilot valve with various electrical connection possibilities.
• Valve body with diaphragm, seat seal and A/B manifolds.
• 2 (B) / 4 (A) service ports plus supply and venting ports 1 (P) / 3 (R), as option with internal thread.
Plug-in connectors or pointed hose nipples.
• The valve can be mounted on the modular pneumatic basic rail Type MP05 to form valve banks.
• Can be mounted in any position, preferably with the magnetic system at the top.
• Manual override for hand operation of the valve
NOTE
The valves require no maintenance, even for dry-air operation.
Valve operations of the Type 5470 valves
3/2 way valve
In de-energised position, pressure inlet 1 closed, outlet port 2 exhausted
3/2 way valve
In de-energised position, pressure inlet 1 connected to outlet port 2
4/2 way valve
In de-energised psotion, pressure inlet 1 connceted to outlet 2, outlet port 4 exhauseted.
NOTE
A simple conversion of the 4/2 way valve to a 3/2 way valve is
possible by closing off one of the service ports:
Service port 2
Service port 4
8 - 5470 / MP05
valve operation C;
valve operation D.