Programming Additional Functions - Conrad 2330830 Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

b) Programming additional functions
By default, the speed controller is preprogrammed with the optimal settings.
When using LiPo drive batteries, check the default setting of the speed controller to see whether the
undervoltage protection is activated (normally 3.2 V per cell). If undervoltage detection is switched off, the
rechargeable battery may be permanently damaged due to deep discharge.
When using a NiMH drive battery, you should switch off undervoltage detection or set it to a lower value
than for LiPo drive batteries.
Programming can be carried out quite easily using the setup button; proceed as follows:
• Switch on the remote control and leave the throttle/brake lever in the neutral position.
• Switch off the speed controller (move the switch to the
"OFF" position).
• Hold down the setup button (B) next to the on/off switch
(A) and turn on the speed controller (move the switch to
the "ON" position).
Keep holding down the setup button (B).
• The LED on the speed controller will flash red and the
motor will beep (keep holding down the setup button).
• The LED will start to flash green after a few seconds
(keep holding down the setup button).
The number of green flashes (1x...5x) indicates the selected setting.
1x flash and 1x beep:
2x flashes and 2x beeps:
3x flashes and 3x beeps:
4x flashes and 4x beeps:
5x flashes and 5x beeps:
Beeps are generated by a brief activation of the brushless motor. This beep can be very quiet depending
on the motor. If this is the case, note the LED indication on the speed controller.
• Wait until the desired setting is indicated (e.g. undervoltage protection = three times green LED flashes and three
times motor beeps), and then release the setup button (refer to the next page for a table with the various setting
options).
• Now the LED flashes red again. The number of red flashing signals indicates which setting value is active (for
example, for undervoltage protection 3.0 V per cell, the LED flashes red four times briefly and the motor emits four
short beeps).
• Press the setup button to change the setting. The number of red LED flashes (and motor beeps) will change ac-
cordingly.
• Turn off the speed controller to exit settings mode and save the programming. If you then turn on the speed control-
ler, it will be ready for operation with the new settings.
• Follow the above steps to change the other settings.
Forward/reverse throttle or forward throttle only
Brake
Low voltage detection for the LiPo battery
Startup mode
Braking power
49

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Reely giant buzz

Table des Matières