STARTER MOTOR (F8CW)
3. Check:
Commutator under cut
Clog/dirty
NOTE:
Remove all particle metal by compressed
air.
4. Check:
Armature coil continuity
Out of specification
Armature coil continuity:
Commutator segments
Segment - Laminations
Segment - Shaft
CHECKING THE BRUSH HOLDER
1. Measure:
Brush length
Out of specification
Brush length limit:
9.0 mm (0.35 in)
2. Check:
Brush holder continuity
Out of specification
Brush holder continuity:
1
Brush holder
8-23
Clean.
Replace.
Continuity
No continuity
No continuity
a
Replace.
Replace.
2
- Base
No continuity