AVENTICS | EtherNet/IP™ | R412012728–BDL–001–AC
5.2.2

Input/output modules

Input/output modules with releasable plug connections allow electrical input and
output signals to be output via the valve system's bus connection.
Input as well as output modules can be connected to the valve system with bus coupler
in any combination not exceeding 6 modules in total. Any order may be used.
Make sure to stay within the load limits.
The bus coupler supplies the inputs for the input modules. The maximum total current
for all inputs is 0.7 A.
The output module is supplied via an M12 connection, with one power supply each for
4 outputs (see tab. 13 on page 57).
5.2.3

Input modules

The input modules used to connect electric sensor signals are available in
two versions:
8x M8 (RMV04-8DI_M8) or
4x M12, double-assigned (RMV04-8DI_M12)