6.2 SOFTWARE INSTRUCTIONS
6.2.1 PASSWORD
Press "PRG" on the master board to enter the programming mode.
The following programming menu is displayed:
Press ENTER. The machine awaits 10 seconds before starting to heat the
water in the boiler.
The date will be stored in a safe area of the circuit board.
Enter Programming via Password 22933 to restore the first installation mode.
Unless specified otherwise, the functions of the above keys are considered
valid throughout the rest of the procedure set out in this manual.
The 5-digit code can range from 00000 to 99999. The code entered is com-
pared with the following:
– complete menu: the complete programming menu is displayed.
– reduced menu: the reduced menu is displayed, i.e. only items enabled
by Windows.
– sales menu: the sales menu only is displayed.
– password for first machine test: this gives access to testing inside the
vending machine (90009).
– password for subsequent machine test: this gives access to testing inside
the vending machine, if the machine had already been tested (99011).
If a password coincides with that of another function, priority is given on the
basis of the order listed above.
6.2.2 MACHINE MENU
The first line of the main menu shows "Select menu", the second line shows
the items to be programmed, making reference to the following list:
Options
Temperature
Pre-selections
Doses
Time and thresholds
Motor extra-time (only visible if at least a Cold slave is connected)
Payment systems
Prices
Price selections
Discounts
Promotions
(provided, not managed)
Preventive action
Decounters
(provided, not managed)
Sales
Clock
Default data
Remote connection (Only visible if a modem is installed (provided, not managed)
Item Number
Configuration
Press the programming key again or hold down the ESC key for 1.5 seconds
to exit the main menu and return to normal state.
6.2.3 MAINTENANCE
Maintenance is performed by pressing the key 'Service'.
In line 1 "Maintenance xxx" will be displayed , where xxx displays the boiler
temperature, and in line 2 the possible detected alarms.
Pressing twice the key Service, the stand by heating phase will be bypassed,
allowing you to perform test selections even on non regimen temperatures.
Pressing a key the slave boiler temperature will be displayed in scroll.
The maintenance panel has the following functions
Some items can be disabled and be visible only in the case of combination
machine with Coffee to Go module.
23