LiFePO4 ) with BMS(***)
10
11
12
13
14
15
Some specific settings are possible – please consult us.
(*) Voltage on + BAT with 10% of the rated current and a tolerance of +/- 1%.
(
)
**
REFRESH is not advised for certain types of AGM batteries
(***) Battery Management System
3.3.3 Programming field 2 : Select special mode
From the programming mode field 1, press for 1 second the button "P"
The ON led emits two successive flashes (see chaper 3.3.15.)
With the two + or - buttons, you can change the programming value
The internal programming can be read by counting the number of flashes on the green LED "FLOATING / REFRESH"
To exit the programming mode, go to programming field 3 and press the P key for 1 second.
-
The BOOST function allows a faster charging of the batteries. This function is timed in time (see section 3.3.2.)
And is automatically inhibited if the battery is charged: shutdown of the BOOST for a battery current <20% of
the nominal current of the charger (12% in the case of the Lithium curve Iron Phosphate with BMS).
-
The REFRESH function allows to apply a voltage step periodically to maintain the battery, to promote its
equalization and thus prevent possible sulfating.
3.3.4 Programming field 3 : Select Can adress
From the programming mode field 2, press for 1 second the button "P"
The ON led emits three successive flashes (see chaper 3.3.15.)
With the two + or - buttons, you can change the programming value
The internal programming can be read by counting the number of flashes on the green LED "FLOATING / REFRESH"
Lithium Iron Phosphate (
STORMLINE Bat
OFF
OFF
Setting
0
1
2
3
13.8V/27.4V
14.4V/28.8V
13.7V/27.4V
14.5V/29V
12V/24V
12V/24V
12V/24V
12V/24V
12V/24V
12V/24V
Programming with CAN bus
Programming with UNI-DISPLAY-R
REFRESH
mode
OFF
OFF
ON
ON
6H
2H
0H
0H
0H
BOOST
mode
OFF
ON
OFF
ON
10H
6H
0H
0H
0H