3.3.7 Programming field 6 : input start up voltage
From the programming mode field 5, press for 1 second the button "P"
The ON POWER led emits six successive flashes (see chaper 3.3.15.)
With the two + or - buttons, you can change the programming value
The internal programming can be read by counting the number of flashes on the green LED "FLOATING / REFRESH"
To exit the programming mode, press the P key for 1 second.
Output Current
Iout = 0A
Setting
0
1
2
3
4
5
6
7
8
9
10
0.5V ( for 12V input )
1.0V ( for 24V input )
Setting
Offset en mV
0
1
2
3
4
5
6
7
Input startup
voltage for 12V
input voltage
10V
10.4V
10.8V
11.2V
11.6V
12V
12.4V
12.8V
13.2V
13.6V
14V
Input startup
voltage
-400
-300
-200
-100
0
100
200
300
Input startup for
24V input voltage
20V
20.8V
21.6V
22.4V
23.2V
24V
24.8V
25.6V
26.4V
27.2V
28V
Iout = Nominal current
Input Voltage
34