Programming Field 2 : Select Special Mode; Programming Field 3 : Select Can Address - Cristec YPOWER Série Manuel Utilisateur

12v/60a mppt; 24v/30a mppt
Masquer les pouces Voir aussi pour YPOWER Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

13
14
15
Some specific settings are possible – please consult us.
(*) Voltage on + BAT with 10% of the rated current and a tolerance of +/- 1%.
(
)
**
REFRESH is not advised for certain types of AGM batteries
(***) Battery Management System

3.3.3 Programming field 2 : Select special mode

-
The BOOST function allows a faster charging of the batteries. This function is timed in time (see section 3.3.2.)
And is automatically inhibited if the battery is charged: shutdown of the BOOST for a battery current <20% of
the nominal current of the regulator (12% in the case of the Lithium curve Iron Phosphate with BMS).
-
The REFRESH function allows to apply a voltage step periodically to maintain the battery, to promote its
equalization and thus prevent possible sulfating.

3.3.4 Programming field 3 : Select Can address

Specific
Specific
Specific
Setting
0
1
2
3
Setting
REGULATOR_Frame1
Can address
0
0x0002 9000
0x0002 9001
1
0x0002 9002
2
0x0002 9003
3
0x0002 9004
4
0x0002 9005
5
0x0002 9006
6
0x0002 9007
7
Programming with RS485
13.8V/27.6V
14.4V/28.8V
Programming with CAN bus
13.8V/27.6V
14.4V/28.8V
Programming with UNI-DISPLAY-R
13.8V/27.6V
14.4V/28.8V
REFRESH
mode
OFF
OFF
ON
ON
Setting
8
9
10
11
12
13
14
15
2H
2H
2H
BOOST
mode
OFF
ON
OFF
ON
REGULATOR_Frame1
Can address
0x0002 9008
0x0002 9009
0x0002 900A
0x0002 900B
0x0002 900C
0x0002 900D
0x0002 900E
0x0002 900F
4H
4H
4H
33