This is a recommendation for installation rather than an obligation. The installing electrician should decide whether or
*
not to use shielded cable depending on the EMC environment.
3.3
-
SETTING
ADJUSTMENT
3.3.1 Description
The YPOWER chargers are equipped with
3.3.2.) ,Can bus address (see chaper 3.3.9.) and special mode (see chaper 3.3.3.).
3.3.2 Programming field 1 : Select type of batteries
To enter programming mode, press the "P" button for 1 second
The ON led flashes (see chaper 3.3.15.)
With the two + or - buttons, you can change the programming value
The internal programming can be read by counting the number of flashes on the green LED "FLOATING / REFRESH"
To exit the programming mode, go to programming field 2 and press the P key for 1 second.
Configuration according to type of batteries 12V or 24V
setting
0
1
2
3
4
5
6
7
8
-
INDICATORS
buttons
Description of the battery type
Opened type bat
free electrolyte (wet)
Classic sealed type bat
(Sealed Lead)
GEL type bat
AGM type bat**
Spiral type bat
Tin calcium lead bat
Wintering or standby sealed
bat
Stabilized DC power supply
SPE1 open type bat
to configure the charger according the battery type (see chaper
Voltage* with
Voltage* with
BOOST OFF
BOOST ON
13.4V/26.8V
14.1V/28.2V
13.8V/27.4V
14.4V/28.8V
14.4V/28.8V
13.8V/27.4V
13.6V
14.4V/28.8V
13.8V/27.4V
14.4V/28.8V
14.4V/28.8V
15.1V
13.4V/26.8V
13.4V/26.8V
12V/24V
12V/24V
13.1V/26.2V
14.8V/29.6V
Maximum
Maximum duration
duration of
of ABSOPTION at
BOOST at
+/- 5% T
+/- 5% T
BOOST
2H
4H
2H
4H
2H
4H
2H
4H
2H
4H
2H
4H
0H
0H
0H
0H
2H
4H
ABS
31