DESCRIPTION DES CONNEXIONS
]
LINE
connexion au système 2Voice
]
POWER connexion alimentation dédiée 1083/20
}
S+
signal de répétition d'appel
S-
CARACTÉRISTIQUES TECHNIQUES
Alimentation (POWER):
Consommation max.:
Tension commutable max. S+, S-:
Courant commutable max.:
Température de fonctionnement:
58
48Vcc ±10%
140mA
30Vcc
100mAcc sur charge résistive
-5 ÷ 45°C
§
DS1083-017
DS1083-017
VD.007 - Floor call button.
VV.004 - Note: on the last column
interface do not remove the
jumper between terminal
pins Z.
VV.008 - Set the dip-switch "1" to
OFF position.
VV.010 - Parameters configuration
Switchboard:
- System in column: 1(YES).
- Associated monitor: 1(YES).
VX.008 - Connect the devices to a
filter and to a protection
device for the power supply
line.
Ref.1332/85
Ref.1332/86
PROTECTION
FILTER
(NEUTRAL)
N
2
2
2
2
GROUND
(PHASE)
L
1
1
1
1
IN OUT
IN
OUT
L
N
USER
VX.021 - On the device/s cut or remove
jumpers:
a) between terminal pins "Z".
For the connection of devices present in
diagrams, see the respective instruction
manuals.
VD.007 - Touche dʼappel à lʼétage.
VV.004 - Remarque: sur la dernière
interface de colonne, il ne
faut pas enlever le pontet
entre les bornes Z.
VV.008 - Configurer le dip-switch "1"
en position OFF.
VV.010 - Configuration des Paramètres
Centrale:
- Système en colonne: 1(OUI).
- Moniteur associé: 1(OUI).
VX.008 - Connecter les dispositifs à
un filtre et à un dispositif
de protection pour la ligne
dʼalimentation.
Réf.1332/85
Réf.1332/86
PROTECTION
FILTRE
(NEUTRE)
N
2
2
2
2
TERRE
(PHASE)
L
1
1
1
1
IN OUT
IN
OUT
L
UTILISATEUR
VX.021 - Sur le/les dispositif/s
couper ou enlever les
pontets:
a) Entre les bornes "Z".
§
Pour la connexion des différents dispositifs
présents dans les schémas, voir les livrets
d'instructions respectifs.
N
59