System configuration in column = NO
column
interface
power supply
door units
switchboard
interface
power supply
power supply
main call stations
CALL REPEAT (S+, S-)
In this screen the user can defi ne if the ringer repeat must be activated or not and if this must be activated
only for special call types; the following screen appears:
(0=NO,1=EX,2=IN,3=A)
The values selectable with the buttons
0
call repeat on S+ and S- disabled
1
call repeat on S+ and S- enabled only for calls coming from main call stations
2
call repeat on S+ and S- enabled only for calls coming from apartment stations
3
call repeat on S+ and S- enabled for all the calls
Press the button
(7) to confi rm and go to the next screen.
COMMUNICATION INTERRUPTION
In this screen the user can defi ne if the interruption of a call during off-hook waiting time or assured
communication time must be enabled or not.
During a call, a conversation, or an auto-on function with or without audio, the involved column or, more
22
secondary
column
call
interface
stations
power supply
power supply
S+ S-
1
and
(18) are:
in general, the system devices in busy state, can be interrupted or not by a call coming from a call station,
according to the confi guration of this switch.
secondary
call stations
To set this parameter, use the buttons
to the next screen.
This value must be the same as that confi gured in system call stations.
POWER-ON PASSWORD
In this screen the user can set the password required when the switchboard is turned on.
Press the button X (13) to delete the current password and enter the new one, using the numeric keypad
(12). The password can be composed by 6 numeric characters max.
If the user does not want to protect the switchboard power-on with a password, set it to 000000.
When the parameter has been confi gured, press the button
USER CODES TYPE
In this screen it is possible to confi gure the user code type, physical or logical.
–
Physical code: users are called with a 5-digit code as follows: ccnnn, where cc indicates the riser column
(from 00 a 31) and nnn indicates the number of the apartment (from 000 a 127)
–
Logical code: users are called with a a number of 1 to 4 digits from 1 to 9999. To use the logical codes,
the names must be programmed, assigning the logical call code to the physical code of the apartment.
To set this parameter, use the buttons
to the next screen.
§
In order to use logical code type, each code must be associated to a physical code in the directory.
DS1083-017
DS1083-017
INT. COMM.
0
(0=NO , 1=YES)
and
(18) and press the button
PASSWORD
000000
(7) to confi rm and go to the next screen.
CODE TYPE
0
(0=PHYSIC, 1=LOGIC)
and
(18) and press the button
(7) to confi rm and go
(7) to confi rm and go
23