5.1.3.1
Cleaning the gauge glass
P.
U.
Fig. 8 Placing the sight glass cover
AA.
AB.
AH.
AG.
Fig. 9 Placing and removing the gauge glass
cover
AA. cover
AB. container edge
AC. the sight glass holder
AD. notch
AE. gauge glass
AF. o−ring
AG. tab
AH. spring
ECopyright Bravilor Bonamat B.V.
WARNING
n If the coffee container (U.) is not completely
AA.
empty, during removal of the gauge glass
(AE.) hot water or coffee can flow over the
AB.
hands.
D Clean the gauge glass (fig.8 ):
AC.
D Make sure that the coffee container (U.) is
completely empty.
AD.
D Take the filter unit (P.) off the coffee
container (U.).
AE.
D Remove the cover (AA.) of the gauge glass
holder (AC.) by pulling this forward and
upward between thumb and forefinger. Hold
AF.
the gauge glass with the other hand.
D Put the forefinger on top of the gauge glass
(AA.) and move the glass a little bit forward.
D The gauge glass (AE.) is clamped with an
O−ring (AF.) at the bottom of the gauge
glass holder (AC.). Therefore take the
gauge glass between thumb and forefinger
and carefully pull it upward while turning it to
and fro.
D Clean the gauge glass and the notch (AD.)
in the gauge glass holder (AC.) with the
supplied sight glass brush.
D Moisten the bottom side of the gauge glass
a little. Carefully push the gauge glass back
into the notch (AD.) and O−ring (AF.) of the
sight glass holder.
D Place the cover (AA.) back onto the gauge
glass holder (AC.). For this hold the cover
between thumb and forefinger and place it at
an angle against the container wall. Press
with the forefinger the cover on the gauge
glass holder in such a way that the cover
falls under the container edge (AB.). Make
sure that the tab (AG.) of the cover falls
behind the spring (AH.) of the gauge glass
holder.
D Place the filter unit (P.) back onto the coffee
container (U.).
TIP
− Make sure that the tab (AG.) of the cover falls
behind the spring (AH.) of the gauge glass
holder.
CAUTION!
− The other maintenance activities (§ 5.2) are
reserved to users with extended authority.