Transport
6.3.3 Replacing the filter
WARNING
No protection without filter!
► Do not use the device without filter.
CAUTION
Damage to blower unit due to penetration of particles!
► Make sure when you remove the filter that no particles
enter the device through the suction inlet.
If a prefilter is used, the prefilter must be inserted between
the splash guard cover and the filter.
The filter changing process may differ depending on the filter
type used.
Particle filter
Removing the filter:
1. Push filter lock button.
2. Fold out splash guard cover with filter (Figure A).
3. Remove the used filter (Figure B).
Inserting the filter:
1. Check rubber seal on filter for damage.
2. Insert new filter into splash guard cover so that the filter is
firmly seated in the splash guard cover.
3. Hook the two lower connection points of the splash guard
cover at an angle into the blower unit sockets.
4. Fold splash guard cover in until it audibly snaps into place
at the filter lock button.
Gas or combination filter
Removing the filter:
1. Push filter lock button.
2. Fold filter with splash guard cover out (Figure A).
3. Dismantling the splash guard cover:
a. Press on the centre of the upper splash guard cover
edge until it snaps out.
b. Fold out splash guard cover (Figure B).
24
A
A
Inserting the filter:
1. Check rubber seal on filter for damage.
2. Place splash guard cover with its lower edge at an angle
on the filter.
3. Push on splash guard cover until it snaps audibly into
place.
4. Hook the two lower connection points of the filter at an
angle into the blower unit sockets.
5. Fold filter in until it audibly snaps into place at the filter lock
button.
6.3.4 Check the flow rate and warning devices
1. Make sure that a filter is inserted.
2. Connect the plug-in connector of the breathing hose to the
blower unit.
3. Switch on the blower unit by pushing the
control panel for approx. 2 seconds.
 After it is switched on, the device performs a self-test.
If the device does not work properly or warning
devices are triggered, eliminate the fault.
4. Cover the open end of the breathing hose with the palm of
your hand.
 The blower unit starts operating more intensively after
about 5 seconds. An alarm is triggered after about
B
20 seconds.
Have the blower unit checked if the rotational speed
remains unchanged and no alarm is triggered.
5. If you wish, you can switch off the blower unit by pushing
the
button on the control panel once again.
6.3.5 Replacing the O-ring at plug-in or bayonet-
type connectors of breathing hoses
1. Use the O-ring removal tool to lift the old O-ring out of the
groove.
2. Insert new O-ring in the provided groove.
3. If required, lubricate the new O-ring with Molykote 111.
7
Transport
Transport in the original packaging or in optionally available
transport box.
8
Storage
Storing the whole system:
– Remove filter and rechargeable battery.
– Dry the components in a container or cabinet. Store them
dry and clean and protect them from direct sunlight and
B
thermal radiation.
Storing rechargeable batteries:
– Deeply discharged batteries may get damaged after
prolonged storage. Charge the rechargeable batteries to
50 to 70 % prior to storage.
– If storage lasts for over 6 months, charge the
rechargeable batteries intermittently.
– Do not store rechargeable batteries for prolonged periods
outside the recommended temperature range. This might
reduce the remaining capacity and number of potential
charge cycles.